2e-3 Plumbing Configurations (Continued)
Figure 9 -
(Existing Pool, Pool Spa Combination, ICS, Solar):
· Manifold to be plumbed between the filter and heater.
· TrioPure
TM
return port of the bypass manifold capped off.
· Return from TrioPure
TM
plumbed to the line of the ICS that goes to the lowest point of the pool.
- This is after the ICS diverter valve.
- A light duty check valve must be placed between the diverter valve and the point where TrioPure
TM
enters the ICS line.
· An automated shut-off valve needs to be put in the line between the bypass manifold and the TrioPure
TM
, which is tied into
the Pool/Spa control system, and shuts off water to the TrioPure when in spa mode.
- If this is overlooked, the TrioPure
TM
will pump water from the spa into the pool, when in spa mode.
· Del recommends installing 2 cm (¾”) ball valves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for
cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell.
Special Note about Spillway Valves on Pool/Spa Combinations without Solar.
If a spillway valve is used, the line which takes water
from the pool into the spa creating the overflow effect, it must be equipped with a light duty check valve to prevent water from being
diverted back into the pool, when in spa mode, and any lines to or from the TrioPure must be plumbed after it.
J
A
J
ICS
POOL
J
SPA
SOLAR
HEATER
TrioPure
TM
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459