4
TrioPure
TM
Sanitation System
2e-3 Plumbing Configurations Figures 1-9
Figure 1 -
(New Pool, Pool Only, No ICS, No Solar, Solar):
· Manifold to be plumbed between the filter and heater. In the case of Solar, the manifold is to be installed before the
diverter valve that serves both the solar and non-solar heaters.
· TrioPure
TM
return port of the bypass manifold capped off.
· Return from TrioPure plumbed to a dedicated 2 cm (¾”) return to the lowest point of the pool.
· To minimize the size of ozone bubbles, use a dispersion cap or main drain cover. This may require a stub-up to the
appropriate size for the fitting.
· Del recommends installing 2 cm (¾”) ball valves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for
cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell.
Figure 2 -
(Existing Pool, Pool Only, No ICS, Solar, No Solar):
· Bypass Manifold plumbed between the filter and heater.
Note
-In the case of Solar, the manifold is to be before the diverter valve that serves both the solar and non-solar heater
s.
· TrioPure
TM
return port of the bypass manifold capped off.
· Return from TrioPure
TM
plumbed into tee after the heater(s).
Note
-In the case of Solar the TrioPure return is to be after the tee where the solar heater joins the main return.
· Del recommends installing 2 cm (¾”) ball valves on the inlet and outlet of the Triopure to facilitate Salt Cell removal for
cleaning and a ball valve after the Bypass Manifold to control water flow through the Salt Cell.
A
SOLAR
HEATER
POOL
Optional
A
POOL
SOLAR
HEATER
Optional
TrioPure
TM
TrioPure
TM
DEL Ozone · San Luis Obispo, CA 93401 · USA · 800-676-1335 · Fax: 805-541-8459
Содержание TrioPure 25