installation manual

1

Before Starting Assembly, please
check contents are as follows:

2

White Felt Filter with black tube

2

Silexa Filters

1

Connecting Yoke (Large blue figure 8)

1

Test Bottle

4

Metal Retaining Springs (400mm)

2

900 ST Towers

2

Lids (only one drilled)

Service interval kit comprising;

• moulded plastic mount + screw
• printed card
• self-adhesive Timestrip.

Fitting kit containing;

2

Straight adaptor 15mm x 1/2” BSP

2

Blanking Plugs - large

4

Elbow 15mm

1

Assembled Porting Block

6

Porting Block Small Blanking Plugs

4

All-Thread Screws (M5 x 87mm)

8

Sleeve Nut Ends (M5 x 9 x 20mm)

3

Stem Adaptors

2

Reducing Bush

1

T-Piece

2

Grab Taps

2

Black Tube 180mm x 15mm Dia.

2

Blue Tube 225mm x 15mm Dia.

Insert the boss on the reverse of
the mount 

(c)

into the pre-drilled

hole in the separator lid. 

Peel backing from timestrip

(a)

and attach to the plastic card

(b)

within the dotted lines. 

Flex the card, passing the ends
through the slots on the top
surface of the mount. 

To activate,

press firmly on 

the timestrip label at the 
point indicated.

After a few minutes a red line 
will appear, to indicate ‘time in
service’ up to 12 months

A replacement card and 
timestrip will be supplied with

each service kit

.

i

ii

iii

General Installation notes

Please ensure a steady 
fall in the pipe run from 
the outlet point to the 
foul drain.

Never discharge 
condensate to a storm 
drain or to surface water; 
always connect to a foul 
drain or sewer.

Remember that it’s the 
user’s responsibility to 
check with the local 
authority as to the 
permissible discharges 
in their area.

Testing Quality

Replace filters before outlet
cloudiness exceeds the ppm
limit for your region.

Test outlet quality weekly
using kit provided. 

Further information is available on our website below.

(c)

(b)

(a)

Service Indicator - 

assembly and attachment