6
www.debem.it
MARCATURA E INFORMAZIONI GENERALI
MARKINGS AND GENERAL INFORMATION
In compliance with the 94/9/CEE standards, the pumps carry
WKHIROORZLQJLGHQWL¿FDWLRQPDUNV
II 2/2 GD c IIB T135°C
: safety symbol to Din 40012 attachment A.
II 2/2GD
: surface equipment for use in areas with the presence
of gases, vapors or mists in addition to clouds of combustible
dust in the air that occur occasionally during normal opera-
tion (EN 1127-1 par. 6.3), both in external and internal areas
(ZONE 1).
c:
protection by constructional safety (EN 13463-5).
IIB
: Excluding the following products hydrogen, acetylene,
carbon disulphide.
T135°C
&ODVVRIDGPLWWHGWHPSHUDWXUHV7KHSURFHVVHGÀXLG
temperature value must fall within such class range and the
user must comply with the instructions contained in the manual
and with the current laws. Furthermore, the user must take
into account the ignition point of the gases, vapors and mists
in addition to clouds of combustible powder in the air existing
in the area of use.
The technical sheet is deposited with TÜV NORD CERT
Hanover.
De conformidad con la directiva 94/9/CEE, las bombas llevan
ODVLJXLHQWHPDUFDGHLGHQWL¿FDFLyQ
II 2/2 GD c IIB T135°C
: símbolo de seguridad conforme a la DIN 40012
apéndice A.
II 2/2 GD
DSDUDWRGHVXSHU¿FLHSDUDVXXVRHQ]RQDVFRQ
presencia de gases, vapores o nieblas, así como presencia
ocasional en el aire de nubes de polvos combustibles durante
el funcionamiento normal (EN 1127-1 apdo. 6.3), tanto en la
zona externa como en la zona interna (ZONA 1).
c
: aparato con modo de protección de tipo constructivo (EN
13463-5).
IIB
: se excluyen los siguientes productos: hidrógeno, acetileno,
sulfuro de carbono.
T135°C
: clase de temperatura admitida. El usuario debe pro-
FHVDUÀXLGRVFDOLHQWHVFRQIRUPHDGLFKDFODVL¿FDFLyQWHQLHQGR
en consideración las indicaciones de este manual y las disposi-
ciones normativas vigentes. El usuario debe además tener en
consideración las temperaturas de detonación de los gases,
vapores o nieblas, así como las nubes de polvos combustibles
en el aire presentes en la zona de empleo.
El legajo técnico está depositado en el TÜV NORD CERT
de Hannover.
GB
In compliance with the 94/9/CEE standards, the pumps carry
WKHIROORZLQJLGHQWL¿FDWLRQPDUNV
II 3/3 GD c IIB T135°C
: safety symbol to Din 40012 attachment A.
II 3/3GD
: surface equipment used in areas where the presence
of gas, vapors or mists in addition to clouds of combustible
powder in the air is unlikely during normal operation both in
external and internal areas and, if it does occur, it will only
persist for a short period (ZONE 2).
c
: protection by constructional safety (EN 13463-5).
IIB
: Excluding the following products: hydrogen, acetylene,
carbon disulphide.
T135°C
&ODVVRIDGPLWWHGWHPSHUDWXUHV7KHSURFHVVHGÀXLG
temperature value must fall within such class range and the
user must comply with the instructions contained in the manual
and with the current laws. Furthermore, the user must take
into account the ignition point of the gases, vapors and mists
in addition to clouds of combustible powder in the air existing
in the area of use.
The technical sheet is deposited with TÜV NORD CERT
Hanover.
De conformidad con la directiva 94/9/CEE, las bombas llevan la
VLJXLHQWHPDUFDGHLGHQWL¿FDFLyQ
II 3/3 GD c IIB T135°C
: símbolo de seguridad conforme a la DIN 40012 apéndice A.
II 3/3GD
DSDUDWRGHVXSHU¿FLHSDUDVXXVRHQ]RQDVFRQ
es improbable, o rara y por breves períodos, la presencia de
gases, vapores o nieblas, así como nubes de polvos combustibles
en el aire durante el funcionamiento, tanto en la zona
externa como en la zona interna (ZONA 2).
c
: aparato con modo de protección de tipo constructivo (EN
13463-5).
IIB
: con excepción de los siguientes productos: hidrógeno,
acetileno, sulfuro de carbono.
T135°C
: clase de temperatura admitida. El usuario debe procesar
ÀXLGRVFDOLHQWHVFRQIRUPHDGLFKDFODVL¿FDFLyQWHQLHQGRHQ
consideración las indicaciones de este manual y las disposiciones
normativas vigentes. El usuario debe además tener en consid-
eración las temperaturas de detonación de los gases, vapores
o nieblas, así como las nubes de polvos combustibles en el aire
presentes en la zona de empleo.
El legajo técnico está depositado en el TÜV NORD CERT
de Hannover.
E