37
Should the pump remain inactive for long periods, proceed
as follows
:$51,1*'LVFKDUJHDQ\UHVLGXDOÀXLGIURPWKH
SXPS ,Q FDVH RI GDQJHURXV WR[LF ÀXLGV DQGRU
otherwise noxious products, wash and treat as
suitable:danger of injuries, damage to health and/or death.
1.
:DVKLQWHUQDOO\XVLQJSURGXFWVVXLWDEOHIRUWRWKHÀXLGEH
-
ing pumped.
2.
&ORVHWKHÀXLGLQWDNHDQGGHOLYHU\YDOYHVPRXQWHGRQWKH
pump.
3.
Close the air supply using the three-way valve; this will
discharge any residual pressure.
4.
If you want to store the pump in the warehouse, you must
respect the following:
WARNING: Storage must be in a closed and pro-
tected environment at temperatures ranging from
5 to 45°C, and a humidity level not above 90%.
5.
If the pump was in disuse for a long period of time, circulate
clean water through it for some minutes before restarting it to
avoid incrustations.
En caso de períodos de inactividad prolongada de la bomba,
proceder como se indica seguidamente:
$7(1&,Ï1 YDFLDU HO ÀXLGR D~Q SUHVHQWH HQ OD
bomba. Efectuar un lavado y tratamiento ade-
FXDGRVKDFLHQGRFLUFXODUXQÀXLGRGHWHUJHQWHQR
LQÀDPDEOH FRPSDWLEOH FRQ ORV PDWHULDOHV GH OD ERPED
peligro de incendio, lesiones, daños a la salud y muerte.
1.
Efectuar un lavado interno utilizando productos adecuados
SDUDHOWLSRGHÀXLGRERPEHDGR
2.
&HUUDUORVJULIRVGHODDVSLUDFLyQ\GHODLPSXOVLyQGHOÀXLGR
montados en la bomba.
3.
Cerrar la alimentación del aire con la válvula de 3 vías; se
descargará así la presión residual.
4.
Si se desea guardar la bomba en almacén, es necesario:
ATENCIÓN: la puesta en almacén debe hacerse en
un lugar cerrado y protegido, con temperaturas
entre los 5 y los 45ºC, con un grado de humedad
no superior al 90%.
5.
En caso de que la bomba haya pasado un período prolon-
gado de inactividad, es conveniente hacer circular agua limpia
durante unos minutos antes de ponerla de nuevo en servicio,
para así evitar depósitos de incrustaciones.
!
!
!
!
PUESTA FUERA DE SERVICIO
DECOMISSIONING
GB
6. Pump does not distrib-
utedelivery value stated
on table
6.1
Product intake hose is
badly connected.
6.2
Piping is clogged.
6.3
Fluid is too viscous.
6.4
Balls do not close prop-
erly.
6.5
,QVXI¿FLHQWDLUÀRZ
6.1a
Check.
6.2a
Check and clean.
6.3a
Install larger piping especially on the intake side and
decrease pump cycles.
6.4a
Disassemble the manifolds and clean the seats or both
the balls and the ball seats.
6.5a
Check pressure using pressure gauge installed on th-
HSXPSZKHQLWLVUXQQLQJVHH¿JSDJHLIWKHSUHVVXUHDW
that point is too low in relation to network pressure, checkall
WKH DLU ¿WWLQJV HVSHFLDOO\ VQDSRQ RQHV &KHFN LI DOO DLUFRQ
-
WUROGHYLFHVKDYHDVXI¿FLHQWÀRZUDWH
WARNING: in90% of
FDVHVVWDOORFFXUUHQFHVDUHFDXVHGE\VQDSRQ¿WWLQJV
GB
PROBLEM
POSSIBLE SOURCE
ADVICE
E