5-2
Part No. 001-4008-101/102
Table 5-2 Normal Factory Settings (Bases)
Refer to help files for descriptions of the above fields.
Fields
Full Duplex Base Integra-TR with
other Integra-TR
Redundant Integra-TR Full Duplex
Base with Integra-TR/ Integra-T
RX Unit
TX Unit
Rx Units
TX Units
Network Settings
Compatibility Mode
Integra-TR
Integra-TR and Integra-T
Tx/Rx Mode
Rx Only
Tx Only
Rx Only
Tx Only
Extended Preamble (ms)
0
Network Speed
19200 Full Channel, 9600 Half Channel,
or 2400 Quarter Channel
9600 Full Channel
Tx Time Out
Disable
Tx Online Diagnostics
Yes
Unit Type
Master
Data Delivery
All
Suspend Period (ms)
0
Activity Time-out (sec)
5
Sleep Mode
Disable (N/A)
COM Port
Device Baud
19200
9600
Data fwd timer
Normal
Parity
8 bit, no parity, 1 stop bit
Break
Ignore break
Xmit Control
DOX
Active
DCD Control
Analog Connector
Analog 1
Input
Fan Control
Input
Fan Control
Analog 2
RxTp
Input
RxTp
Ant. SW Control
Frequency
Transmit
User Choice
Receive
User Choice
Adjustments
Carrier Sense (-dBm)
105
(N/A)
110
(N/A)
Power Out
255 (indicates 5 Watts nominal)
Frequency Warp
Grayed out (radio dependant) Values are set at factory; can be changed if required; hit
release test button to enable field
Deviation
Содержание Integra-TR
Страница 1: ...Integra TechnicalManual Version Integra TR S e r v i c e ...
Страница 5: ...1 3 Part No 001 4008 101 102 Figure 1 2 Installation Dimensions ...
Страница 8: ...1 6 Part No 001 4008 101 102 ...
Страница 10: ...1 8 Part No 001 4008 101 102 ...