3-3
Part No. 001-4008-101/102
1 (Unless you set a lower value). Note that readings less than 5 watts may be due to losses in the cables used for testing. Check
your wattmeter frequency calibration curve.
2
If a psophometrically weighted filter is available on the service monitor, use 0.35
µ
V
.
Table 3-1 Tests and Adjustments for One-quarter, Half, and Full Channel Units
Step
Action
Expected Results Measure With
If Not?
1
Output Power
5 W
1
+ 10%, -20%
Service
monitor set to
read power
Adjust using the Field Programming Software
Power Out
setting (255 is the maximum) or refer
to Factory Tech support
2
Frequency Error
Press TX
Unmod
300 Hz
Service moni-
tor set to read
frequency
Adjust using the Field Programming Software
Freq Warp
setting. (Typical adjustment range is
1.5kHz) If found outside limits, call factory
technical support.
3
Deviation
Press TX tone
For any bit rate speeds
selected
Tol. +5%, -10%
For Full channel:
+4.0 kHz
For Half channel:
+2.5 kHz
For One-quarter
channel:
Service monitor
set to read devia-
tion with mid(15-
30 kHz) IF filter
Adjust using the Field Programming Software
Deviation
setting (if required)
4
Carrier Sense
Inject a non-modulated
carrier at -120 dBm to the
Integra-TR RF input;
Raise the service monitor RF
output until the CS LED
comes on
The CS LED should be off
The CS LED should come on within 2
dB from the value set by the Field Pro-
gramming Software:
Default: approx. -105 dBm
(-110 in non-refarmed mode)
The threshold may be raised to prevent false
CS operation in the presence of noise,
intermodulation, or other sources of radio
interference (e.g., for ambient noise at -100
dBm (measured with a spectrum analyzer),
set the CS threshold for -95 dBm)
5
Set the service monitor to generate a -80 dBm signal on the selected receive frequency. The signal
should be modulated with a 1.0 kHz tone at deviation specified below.
Set service monitor IF filter to mid (15-30 kHz), no audio filter.
Note: Use test audio (pin 4) of the power/analog connector (white lead) for SINAD and distortion
6
Demodulated Audio
Press
CHK
For any bit rate speeds
selected:
For Full channel unit: set
deviation to +4 kHz
For Half channel unit: set
deviation to + 2.5 kHz
For Quarter channel unit:
1 Vpp + 0.1
If read at Test audio pin 4 of PWR
analog connector
Adjust using
RXA adjust setting
(if required)
7
12 dB SINAD
Set service monitor IF filter to
mid (15-30 kHz)
For Full channel unit: set
deviation to +3 kHz
For Half channel unit: set
deviation to + 1.5 kHz
For Quarter channel
unit:
< 0.5
µ
V
2
Service monitor
set for
SINAD
Refer to Factory Technical Support
8
Distortion
Set service monitor IF filter to
mid (15-30 kHz)
Deviation
level as per SINAD above
< 3%
Service monitor
set for
DISTORTION
Refer to Factory Technical Support
Содержание Integra-TR
Страница 1: ...Integra TechnicalManual Version Integra TR S e r v i c e ...
Страница 5: ...1 3 Part No 001 4008 101 102 Figure 1 2 Installation Dimensions ...
Страница 8: ...1 6 Part No 001 4008 101 102 ...
Страница 10: ...1 8 Part No 001 4008 101 102 ...