2-19
Part No. 001-4008-101/102
Block Delay (s)
Block Delay (s) allows the user to determine the delay between the transmission of data blocks in 0.25
second intervals (0.00 to 10.00 seconds).
Clear
Clear allows the user to clear the display (blocks transmitted, responses received, blocks received and link
quality).
Start
Start is used to begin the test.
Pause
Pause is used to pause the test and allows the user to resume the test at a later time.
2.4.10 Offline Diagnostics
Offline Diagnostics are returned from a local or remote unit in response to a Get Diags request (see Figure
2-18). An Offline Diagnostics request requires suspension of network operation. Offline Diagnostics
parameters include the following:
z
Unit ID: the Short ID of the unit sending diagnostics
z
RSSI Level: Received Signal Strength Indication (in dBm)
z
Battery Voltage: supply voltage
z
Temperature: internal case temperature (in Celsius)
z
Forward Power: Forward Power (in watts)
z
Reverse Power: Reverse Power (in watts)
z
Analog Input 1: voltage on the External Analog 1 Input from the Power/Analog connector (in volts)
z
Analog Input 2: voltage on the External Analog 2 Input from the Power/Analog connector (in volts)
z
Preamble Good: the number of correctly decoded transmissions received in the last 15. Used with Pream-
ble Total, this serves as an indication of how well the unit is receiving data
z
Preamble Total: the number of total transmissions detected, maximum is 15. Used with Preamble Good,
this serves as an indication of how well the unit is receiving data.
Local ID
The Local ID button allows the user to send commands to the local unit (the unit interfaced to the
computer). The Short ID for this unit is shown.
Remote ID
The Remote ID button allows the user to send commands to any specific remote unit and obtain its
diagnostic information. The Remote ID is selected from the list of Remote IDs set up in the Diagnostic IDs
and Alarms screen.