80
A-Class
Step
Action
Displayed Message
Comment
K
In the table, where both
the Label Value and TOF
Value are at least 20,
subtract the amounts and
record the result as a
Difference Value (see
below).
Identify the largest
Difference Value and then
the corresponding Gain
Number.
GAIN TRAN
*31 (0 - 31)
<yyy>
- Or, for reflective media:
GAIN REFL
*31 (0 – 31)
<yyy>
•
In this example, Gain
Number 18 is chosen
because, where both
values are at least
twenty, it has the
highest Difference
Value.
•
This Gain Number will
be used to resample
the media.
Sample Calibration Table
Gain Number
Label Value
TOF Value
Difference Value
00 252 248 4
01 250 245 5
02 248 234 14
… … … …
15 188 63 125
16 184 51 133
17 179 38 141
18
174
25
149
19 170 19 N/A
… … … …
31 132 14 N/A
Step
Action
Displayed Message
Comment
L
Scroll to the Gain Number
determined in the
previous step and then
press the ENTER Key.
GAIN TRAN
*18 (0 - 31)
<yyy>
- Or, for reflective media:
GAIN REFL
*18 (0 – 31)
<yyy>
After ENTER is pressed,
an asterisk (*) appears
to denote selection.
(continued)
Содержание A-Class Mark II
Страница 1: ...Operator s Manual ...
Страница 2: ......
Страница 5: ......
Страница 20: ...10 A Class Peel Point Dimension See Appendix C for the PE Series printer s dimension Peel Bar ...
Страница 80: ...70 A Class ...
Страница 113: ...A Class 103 ...
Страница 115: ...A Class 105 ...
Страница 126: ...116 A Class ...
Страница 134: ...124 A Class ...
Страница 138: ...128 A Class ...
Страница 142: ...132 A Class ...
Страница 156: ...146 A Class ...
Страница 158: ...148 A Class ...
Страница 164: ...154 A Class ...