MATRIX 450N™ REFERENCE MANUAL
74
4
4.6 OUTPUTS
Two optocoupled general purpose outputs are available. The meaning of the two outputs
Output 1 and Output 2 can be defined by the user. They are typically used either to signal the
data collection result.
CBX100/500
Function
+V
Power Source - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
-V
Power Reference Outputs
The electrical features of the two outputs are the following:
V
CE
= 30 Vdc max.
I
CE
= 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
= 1 Vdc max. @ 10 mA
P
D
= 90 mW Max. @ 50 °C ambient temp.
By default, Output 1 is associated with the No Read event, which activates when the code(s)
signaled by the external trigger are not decoded, and Output 2 is associated with the Good
Read event, which activates when all the selected codes are correctly decoded.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the DL.CODE parameters Help On Line for further details.
Содержание matrix 450N
Страница 1: ...REFERENCE MANUAL Matrix 450N...
Страница 12: ...xii...
Страница 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 37 ID NET Network Connections with isolated power blocks...
Страница 78: ...MATRIX 450N REFERENCE MANUAL 66 4 Figure 38 ID NET Network Connections with Common Power Branch Network...
Страница 79: ...CBX ELECTRICAL CONNECTIONS 67 4 Figure 39 ID NET Network Connections with Common Power Star Network...
Страница 83: ...CBX ELECTRICAL CONNECTIONS 71 4 Figure 43 NPN External Trigger Using CBX Power...
Страница 137: ...SOFTWARE CONFIGURATION 125 7 ID NET Master ID NET Slave 1 ID NET Slave 2...
Страница 139: ...SOFTWARE CONFIGURATION 127 7 Open the cloned application job...
Страница 175: ......