64
4
4.3.2 ID-NET Response Time
The following figure shows the response time of the ID-NET network. This time is defined as
the period between the Trigger activation and the beginning of data transmission to the Host.
Max ID-NET Response Time
240
220
200
180
160
140
120
100
80
60
40
20
0
R
es
pons
e Tim
e (m
s)
Number of Nodes
500 kbps
250 kbps
125 kbps
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
Figure 36
– ID-NET Response Time
CONDITIONS:
ID-NET M/S Synchronized layout
message length = 50 bytes per node
4.3.3 ID-NET Network Termination
The network must be properly terminated in the first and last reader of the network. This is
done by setting the ID-NET Termination Resistance Switch in the CBX100/500 to ON.