MATRIX 450N™ REFERENCE MANUAL
58
4
4 CBX ELECTRICAL CONNECTIONS
All Matrix 450N models can be connected to a CBX connection box through one of the
available
CAB-MSxx
accessory cables. These accessory cables terminate in a 19-pin
connector on the Matrix 450N side and in a 25-pin male D-sub connector on the CBX side.
We recommend making system connections through one of the CBX connection boxes since
they offer the advantages of easy connection, easy device replacement, and filtered
reference signals.
NOTE:
If you require direct wiring to the reader the connections are the
same as shown in this chapter with the exception of the digital Outputs. Direct
wiring details are indicated in Appendix A.
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the Matrix 450N reader is connected by means of the CBX100/500:
CBX100/500 Terminal Block Connectors
Input Power
Vdc
Power Supply Input V
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Inputs
+V
Power Source
– External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference
– External Trigger
+V
Power Source
– Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference
– Inputs
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
ID-NET
REF
Network Reference
ID+
ID-NET n
ID-
ID-NET network -
Shield
Network Cable Shield
Main Interface
RS232
RS422 Full-Duplex
TX
TX+
RX
*
RX+
-
TX-
-
*
RX-
SGND
SGND
*
Do not leave floating, see par. 4.2.2 for connection details.
Содержание matrix 450N
Страница 1: ...REFERENCE MANUAL Matrix 450N...
Страница 12: ...xii...
Страница 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 37 ID NET Network Connections with isolated power blocks...
Страница 78: ...MATRIX 450N REFERENCE MANUAL 66 4 Figure 38 ID NET Network Connections with Common Power Branch Network...
Страница 79: ...CBX ELECTRICAL CONNECTIONS 67 4 Figure 39 ID NET Network Connections with Common Power Star Network...
Страница 83: ...CBX ELECTRICAL CONNECTIONS 71 4 Figure 43 NPN External Trigger Using CBX Power...
Страница 137: ...SOFTWARE CONFIGURATION 125 7 ID NET Master ID NET Slave 1 ID NET Slave 2...
Страница 139: ...SOFTWARE CONFIGURATION 127 7 Open the cloned application job...
Страница 175: ......