MATRIX 450N™ REFERENCE MANUAL
54
3
3.4.1 EMK-380 Side Mount
– Standard
Matrix 450N and EMK-380 Mirror alignment is maintained when the EMK is mounted directly
to the frame profiles. The skew angle is made at the mirror instead of at the reader.
1. Mount the mirror brackets to the
profiles with one bolt in the center
position and one bolt in the outer
ring.
2. Rotate the mirror brackets so that
the 15° skew angle slot is aligned
with the profile channel, (see the
figure below).
3. Mount the Matrix 450N reader
through the center slots of the L-
bracket to the profile.
4. Move the mirror assembly to the
correct distance from the reader
according to your application.
5. Move the Matrix 450N reader
vertically to center it on the mirror.
6. Tighten the bolts.
15° Skew