CBX ELECTRICAL CONNECTIONS
61
4
4.2 MAIN SERIAL INTERFACE
CAUTION:
Do not connect to the Main Interface spring clamp terminals if
using Host Interface Modules (Fieldbus) with the CBX500.
The signals relative to the following serial interface types are available on the CBX spring
clamp terminal blocks.
The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via DL.CODE software. For more details refer to the Help On Line
page of the Reading Phase step (Channels) in DL.CODE.
Details regarding the connections and use of the interfaces are given in the next paragraphs.
4.2.1 RS232 Interface
The RS232 interface is generally used for Point-to-Point connections. When it is connected
to the host computer it allows transmission of code data.
The following pins are used for RS232 interface connection:
CBX100/500
Function
TX
Transmit Data
RX
Receive Data
SGND
Signal Ground
It is always advisable to use shielded cables. The overall maximum cable length must be
less than 15 m (49.2 ft).
SGND RXD
TXD
USER INTERFACE
SGND TX
RX
READER
Figure 33
– RS232 Main Interface Connections
Содержание matrix 450N
Страница 1: ...REFERENCE MANUAL Matrix 450N...
Страница 12: ...xii...
Страница 77: ...CBX ELECTRICAL CONNECTIONS 65 4 Figure 37 ID NET Network Connections with isolated power blocks...
Страница 78: ...MATRIX 450N REFERENCE MANUAL 66 4 Figure 38 ID NET Network Connections with Common Power Branch Network...
Страница 79: ...CBX ELECTRICAL CONNECTIONS 67 4 Figure 39 ID NET Network Connections with Common Power Star Network...
Страница 83: ...CBX ELECTRICAL CONNECTIONS 71 4 Figure 43 NPN External Trigger Using CBX Power...
Страница 137: ...SOFTWARE CONFIGURATION 125 7 ID NET Master ID NET Slave 1 ID NET Slave 2...
Страница 139: ...SOFTWARE CONFIGURATION 127 7 Open the cloned application job...
Страница 175: ......