1. General:

The MR-10/20 family of magnetic stripe card readers are designed for reading standard or high-coercivity magnetic
stripe cards. The MR-20 also provides a 12-key keypad for PIN entry. The MR-10/20 provides a TTL interface. The
following paragraphs describe instructions for installing and maintaining the card reader.

2. Mounting the reader:

Find a suitable location to anchor the reader mounting bracket. The reader may be mounted vertically or
horizontally. See recommended orientation. The mounting of the reader does not require a junction box. However,
rigid conduit is required for outdoor application. A single gang junction box may be used to provide a transition to rigid
conduit.  If a single gang junction box is used, a wall plate (optional) may be used to cover the junction box. The
reader is then secured to the mounting bracket using a screw. Refer to figures for reader dimensions and typical
junction box usage.

MR-10/MR-20 Magnetic Card Reader

Installation and Maintenance

www.mercury-security.com

2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562) 986-9105 FAX (562) 986-9205

CAUTION: DO NOT DISCONNECT
KEYPAD WITHOUT DISENGAGING
THE CONNECTOR!

3. Reader Wiring:

The reader has a RJ-11 modular jack for easy field connection. A small piece of pre-terminated cable is supplied
with each standard reader for field wiring. The pre-terminated cable has nonstandard color. Refer to pin number
if the pre-terminated cable is not used. Cable with wires of 24AWG or larger are recommended for field wiring.

4. Connecting the Keypad:

The MR-20 reader provides a 12-key keypad for PIN entry. The flex tail of the keypad is connected to the electronic
board via a ZIF (zero insertion force) connector. The contacts are engaged/disengaged  by a moving slide. Care must
be exercised when connecting and disconnecting the keypad. When connecting the keypad to the board, open the
slide as shown. Insert the electronics into the housing and insert flex tail in the ZIF connector. Then, close the slide
to engage the contacts.  To disconnect the keypad, follow the previously described steps in reverse.

CONFIDENTIAL:

 For installation and maintenance use only. 

   DO NOT

 distribute.

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.

Содержание MR-10

Страница 1: ... BEACH CA 90815 1755 562 986 9105 FAX 562 986 9205 CAUTION DONOTDISCONNECT KEYPADWITHOUTDISENGAGING THECONNECTOR 3 Reader Wiring The reader has a RJ 11 modular jack for easy field connection A small piece of pre terminated cable is supplied with each standard reader for field wiring The pre terminated cable has nonstandard color Refer to pin number if the pre terminated cable is not used Cable wit...

Страница 2: ...tying the mounting bracket to earth ground locally e g grounded conduit 8 DIP switch Jumper setting The DIP switch jumper on the MR 10 20 readers are used to select a preset format This preset format determines how the card is interpreted the functions for the LED and buzzer and the output signal format etc Refer to the format specification for detail The settings are for STANDARD models ONLY 5 We...

Страница 3: ...tRange 34 bitRange 8 1 3 000 255 000 999 4 8 00000 65535 00000 99999 9 1 3 000 255 000 999 4 9 000000 065535 000000 999999 10 1 4 0000 0255 0000 4097 5 10 000000 065535 000000 999999 11 or more 1 5 00000 00255 00000 04097 6 11 000000 065535 000000 999999 AMC card 1 6 000000 000255 000000 004097 7 12 000000 065535 000000 999999 Format 6 26 bitWiegandcompatibleoutputfromstandardNorthernComputer32 bi...

Страница 4: ...ed to verify the LED function and the buzzer input for the buzzer function For the MR 20 thereaderwillechoakeypresswithabriefflashofbothLEDsandashortbeepofthebuzzer Resettotherequired format for normal operation after test 12 Maintenance The readers are designed to provide continuous service with minimal routine maintenance However contaminants such as magnetic oxides from badges and dirt tend to ...

Страница 5: ...ie cast aluminum gray powder coat standard Mounting stainless steel Wall plate 18 CRS gray powder coat standard Card 75 bpi ANSI X4 16 Track 2 standard Speed 3 to 50 ips ReadHead 1 000 000 passes typical standard Distance 500 152m with 18 AWG wires Environmental Temperature 55 to 85 degrees C storage 40 to 75 degrees C operating Humidity 0 95 RHNC standard 100 OW option 14 Product Identification R...

Страница 6: ...or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of reconditioned units Returns must be accompanied by a return authorization number RMA obtained from customer service and prepaid postage and insurance Liability ...