INSTALLATION ENVIRONMENT
USER MANUAL
21
INSTALLATION ENVIRONMENT
Control rack
The control rack must be installed in a suitable environment in order to allow proper air
flow and correct housing of the cables.
The control rack uses a forced air cooling system: an adequate air flow is necessary to
guarantee its correct cooling. Install the control rack so that air flow is not obstructed.
Moreover, do not install it near a heat source.
Clean the air filter when it is dirty. If the air filter is dirty, insufficient air-flow might not
ensure correct cooling and might stop the marking operation. Clean or replace the air
filter periodically.
≥
300mm
NOTE
Figure 14: Control rack installation environment
CAUTION
If not enough space is provided, the temperature inside the control rack
could rise, causing temperature error.
CAUTION
DO NOT place heavy objects on top of the control rack!
The control rack IP rating is IP31 in horizontal position, otherwise IP30.