CONNECTORS SPECIFICATIONS
USER MANUAL
39
Device Port 1
Control rack back panel connector
Plug, M12, 8 positions male.
Figure 15: Device Port 1 connector, male panel plug (front view)
Table 6: Device Port 1 connector pinout
(*) see “Input/Output specifications” on page 41
Device Port 2
Control rack back panel connector
Plug, M12, 8 positions male.
Figure 16: Device Port 2 connector, male panel plug (front view)
Table 7: Device Port 2 connector pinout
(*) see “Input/Output specifications” on page 41
PIN
SIGNAL
TYPE*
DESCRIPTION
1
VCC
Power Output
Auxiliary 24V DC power supply (15W max power)
2
GND
Ground
Ground reference
3
EXT_TRIG_#1
Digital Output
Reserved output for MARVIS™
4
EXT_INPUT_#1
Digital Input
Reserved input for MARVIS™
5
RESERVED
-
DO NOT CONNECT
6
INT_RS232_RX
Digital Input
Reserved RS232 for micrometric distance sensor
7
INT_RS232_TX
Digital Output
Reserved RS232 for micrometric distance sensor
8
RESERVED
-
DO NOT CONNECT
BODY
SHIELD
Shield
Connector case provides electrical connection to the body
PIN
SIGNAL
TYPE*
DESCRIPTION
1
VCC
Power Output
Auxiliary 24V DC power supply (15W max power)
2
GND
Ground
Ground reference
3
EXT_TRIG_#2
Digital Output
Reserved output for MARVIS™
4
EXT_INPUT_#2
Digital Input
Reserved input for MARVIS™
5
RESERVED
-
DO NOT CONNECT
6
RESERVED
-
DO NOT CONNECT
7
RESERVED
-
DO NOT CONNECT
8
RESERVED
-
DO NOT CONNECT
BODY
SHIELD
Shield
Connector case provides electrical connection to the body
Содержание Arex 400
Страница 1: ...AREX 400 USER MANUAL InfraRed Fiber Laser Marker ...
Страница 64: ...NOTE SET UP 56 AREX 400 Figure 7 Connecting the monitor Minimum monitor resolution 800 x 600 VGA standard ...
Страница 145: ...USER MANUAL 137 APPENDIX H MECHANICAL DRAWINGS ...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 400 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings ...