TECHNICAL SPECIFICATIONS
38
AREX™ 400
Encoder
Control rack back panel connector
Socket, M12, 8 pins female. Recommended encoder: Datalogic ENC58-S10-XXXX-M12
(ENC58-S10-5000-M12). See “Starter Kit for Marking On the Fly (MOF)” on page 81.
Figure 13: Encoder connector, female panel socket (front view)
Table 4: Encoder connector pinout
(*) see “Input/Output specifications” on page 41
Photocell
Control rack back panel connector
Socket, M12, 4 pins female. Recommended photocell: Datalogic S51-PA-5-B01-PK; Data-
logic S15-PA-5-B01-PK or equivalent. See “Starter Kit for Marking On the Fly (MOF)” on
Figure 14:Photocell connector, female panel socket (front view)
Table 5: Photocell connector pinout
(*) see “Input/Output specifications” on page 41
PIN
SIGNAL
TYPE*
DESCRIPTION
1
GND
Ground
Ground reference
2
VCC
Power Output
Auxiliary 24V DC power supply (750mA max)
3
ENC_A
Digital input
Encoder HTL A channel signal
4
GND
Ground
Return signal for ENC_A
5
ENC_B
Digital Input
Encoder HTL B channel signal
6
GND
Ground
Return signal for ENC_B
7
RESERVED
-
DO NOT CONNECT
8
RESERVED
-
DO NOT CONNECT
BODY
SHIELD
Shield
Shield
PIN
SIGNAL
TYPE*
DESCRIPTION
1
VCC
Power Supply
Auxiliary 24V DC power supply (120mA max)
2
RESERVED
-
DO NOT CONNECT
3
GND
Ground
Ground reference
4
PHOTOCELL
Digital input
PNP photocell signal
Содержание Arex 400
Страница 1: ...AREX 400 USER MANUAL InfraRed Fiber Laser Marker ...
Страница 64: ...NOTE SET UP 56 AREX 400 Figure 7 Connecting the monitor Minimum monitor resolution 800 x 600 VGA standard ...
Страница 145: ...USER MANUAL 137 APPENDIX H MECHANICAL DRAWINGS ...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 400 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings ...