SAFETY FUNCTIONS OF AREX™ 400
USER MANUAL
101
Example 1
Risk Analysis of a fully automatic laser processing machine that operates only when pro-
tection system is disengaged.
•
Operative cycle: 500 pcs/hour, 3 shifts (8h/shift) 350 days/year
•
Dedicated enclosures prevent laser emission also during parts loading/unloading
•
An interlocked door is dedicated to
maintenance and cleaning
•
Maintenance technicians are
SKILLED
on laser risks and have specific
DPI
•
In case of access line is stopped and restarted
LASER RISK ASSESSMENT:
HAZARD, direct and scattered laser radiation:
•
RISK SEVERITY: SEVERE (irreversible eye damage)
•
RISK FREQUENCY:
RARE
(1/month for maintenance)
•
AVOIDANCE PROBABILITY:
POSSIBLE
(with DPI)
RISK REDUCTION:
INTERLOCKED DOOR
Estimation of PLr for door interlock safety function
•
SEVERITY: SEVERE
S2
•
FREQUENCY: SELDOM
F1
•
POSSIBILITY OF AVOIDING HAZARD: POSSIBLE
P1
Severity of injury (S)
S1
Slight (normally reversible injury)
S2
Serious (normally irreversible injury or death)
Frequency and/or exposure time to hazard (F)
F1
Seldom to less often and/or exposure time is short
F2
Frequent to continuous and/or exposure time is long
Possibility of avoiding hazard or limiting harm (P)
P1
Possible under specific conditions
P2
Scarcely possible
PLr = PLc
Restart: manual reset
Door Switch
Safety Controller
Arex™ 400 SLO - Safety Circuit
Input
Logic
Output
PLr=PLc
Содержание Arex 400
Страница 1: ...AREX 400 USER MANUAL InfraRed Fiber Laser Marker ...
Страница 64: ...NOTE SET UP 56 AREX 400 Figure 7 Connecting the monitor Minimum monitor resolution 800 x 600 VGA standard ...
Страница 145: ...USER MANUAL 137 APPENDIX H MECHANICAL DRAWINGS ...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 400 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings ...