CONNECTORS SPECIFICATIONS
USER MANUAL
35
Command Box (Laser Control)
Control rack back panel connector
Socket Sub-D, 25 pins, female.
Figure 9: Command Box connector, female panel socket (front view)
PIN
SIGNAL
TYPE***
DESCRIPTION
1
24V_ENABLE_B
Output power
supply
Auxiliary 24V DC power supply available for EXT_ENABLE_B (max 125mA)
2
EXT_ENABLE_B
Digital Input
Secondary external ENABLE signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
3
GOOD/BAD
Digital Output
This signal is used to notify a bad marking:
- ON in case of bad marking
4
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH (max
125mA)
5
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH (max
125mA)
6
EXT_24V
Output power
supply
Auxiliary 24V DC power supply available for drive input logical HIGH (max
125mA)
7
24V_ENABLE_A
Output power
supply
Auxiliary 24V DC power supply available for EXT_ENABLE_A (max 125mA)
8
EXT_ENABLE_A
Digital Input
Primary external ENABLE signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
9
BUSY
Digital Output
This signal is used to know if the current spooler is executing (marking in
progress):
- ON during marking process
10
CONNECTOR_PRES-
ENCE
Digital Input
This signal is used to check the presence of the Command Box connector:
- HIGH level: normal operation
- LOW level or disconnected: laser marker faulty
11
START_MARKING*
Digital Input
This signal is used to start to the marking process when a document or a
sequence is running in AUTO MODE** or WORK MODE**:
- HIGH level pulsed signal start the marking process
12
EXT_KEY
Digital Input
External KEY signal:
- HIGH level: contact closed
- LOW level or disconnected: contact opened
13
STOP_MARKING*
Digital Input
This signal is used to stop the marking process:
- HIGH level pulsed signal stop the marking process
14
RESERVED
-
DO NOT CONNECT
15
RESERVED
-
DO NOT CONNECT
16
RESERVED
-
DO NOT CONNECT
17
END
Digital Output
This signal is used to know if the marking process is finished:
- ON at the end of marking process
18
POWER_ON
Digital Output
This signal is used to know if the laser marker is already warmed up:
- ON when the laser is in STAND_BY or READY state
19
GND
Ground
Ground reference
20
SYSTEM_ALARM
Digital Output
This signal is used to know if the laser marker is in booting up state or in
error state:
- ON during BOOTING UP
- ON in case of system error
Содержание Arex 400
Страница 1: ...AREX 400 USER MANUAL InfraRed Fiber Laser Marker ...
Страница 64: ...NOTE SET UP 56 AREX 400 Figure 7 Connecting the monitor Minimum monitor resolution 800 x 600 VGA standard ...
Страница 145: ...USER MANUAL 137 APPENDIX H MECHANICAL DRAWINGS ...
Страница 146: ...MECHANICAL DRAWINGS 138 AREX 400 CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 147: ...SCAN HEAD USER MANUAL 139 SCAN HEAD NOTE Please refer to Datalogic website for detailed drawings ...