D-500 User Manual Rev_06 Firmware V-5.8
K35D05-EN - 103 -
Parameter Definition
Unit
Min
Max
Factory
Set
Description
Sender Curve-1 ohm
ohms
0
5000
Point-1 ohm value
Sender Curve-1 value
x
0
10000
Point-1 reading
Sender Curve-2 ohm
ohms
0
5000
Point-2 ohm value
Sender Curve-2 value
x
0
10000
Point-2 reading
Sender Curve-3 ohm
ohms
0
5000
Point-3 ohm value
Sender Curve-3 value
x
0
10000
Point-3 reading
Sender Curve-4 ohm
ohms
0
5000
Point-4 ohm value
Sender Curve-4 value
x
0
10000
Point-4 reading
Sender Curve-5 ohm
ohms
0
5000
Point-5 ohm value
Sender Curve-5 value
x
0
10000
Point-5 reading
Sender Curve-6 ohm
ohms
0
5000
Point-6 ohm value
Sender Curve-6 value
x
0
10000
Point-6 reading
Sender Curve-7 ohm
ohms
0
5000
Point-7 ohm value
Sender Curve-7 value
x
0
10000
Point-7 reading
Sender Curve-8 ohm
ohms
0
5000
Point-8 ohm value
Sender Curve-8 value
x
0
10000
Point-8 reading
Sender Curve-9 ohm
ohms
0
5000
Point-9 ohm value
Sender Curve-9 value
x
0
10000
Point-9 reading
Sender Curve-10 ohm
ohms
0
5000
Point-10 ohm value
Sender Curve-10 value
x
0
10000
Point-10 reading
Sender Curve-11 ohm
ohms
0
5000
Point-11 ohm value
Sender Curve-11 value
x
0
10000
Point-11 reading
Sender Curve-12 ohm
ohms
0
5000
Point-12 ohm value
Sender Curve-12 value
x
0
10000
Point-12 reading
Sender Curve-13 ohm
ohms
0
5000
Point-13 ohm value
Sender Curve-13 value
x
0
10000
Point-13 reading
Sender Curve-14 ohm
ohms
0
5000
Point-14 ohm value
Sender Curve-14 value
x
0
10000
Point-14 reading
Sender Curve-15 ohm
ohms
0
5000
Point-15 ohm value
Sender Curve-15 value
x
0
10000
Point-15 reading
Sender Curve-16 ohm
ohms
0
5000
Point-16 ohm value
Sender Curve-16 value
x
0
10000
Point-16 reading
Sender Name
-
-
-
If the sender type parameter is set to
zero (not used), this string is used as
sender name while displaying the
sender reading.
Sender Low Fault String
-
-
-
If the sender type parameter is set to
zero (not used), this string is used as
sender low value fault in the alarm
display.
Sender High Fault String
-
-
-
If the sender type parameter is set to
zero (not used), this string is used as
sender high value fault in the alarm
display.
Содержание D-500
Страница 35: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 35 4 3 3 PHASE 3 WIRE DELTA 4 2 3 PHASE 4 WIRE STAR ...
Страница 38: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 38 4 9 1 PHASE 2 WIRE 4 8 2 PHASE 3 WIRE DELTA 2 CTs L1 L3 ...
Страница 43: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 43 6 2 AMF FUNCTIONALITY CTs AT ALTERNATOR SIDE ...
Страница 44: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 44 6 3 ATS FUNCTIONALITY ...
Страница 45: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 45 6 4 REMOTE START FUNCTIONALITY ...
Страница 46: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 46 6 5 ENGINE CONTROL FUNCTIONALITY ...
Страница 47: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 47 6 6 REMOTE DISPLAY PANEL FUNCTIONALITY ...
Страница 56: ...D 500 User Manual Rev_06 Firmware V 5 8 K35D05 EN 56 ...