DM-
SV01 Server ● BMC User Manual ● Rev. 2.1
88
Figure 85: Redfish - Power consumption
3.3.5.3.3 Peak Power
Using a GET request, it is possible to retrieve the peak power consumed by the DM-SV01 server.
Function
System Peak Power
Operation
GET
URI
https://<BMC_IP>/redfish/v1/Chassis/chassis/Sensors/PEAK_POWER
Payload
none
Header
X-Auth-
Token: “<token>”
Expected
response
200 OK
Reply
Please, see the example below.
As an example, the excerpt below shows the data provided by the redfish when using the GET request
to retrieve the peak power of the system. The value of the peak power is shown in the “Reading” field.
The measurement unit (Watts) is shown in the “ReadingUnits” field. Additionally, the user can check
the health status of the sensor and the respective warning and critical thresholds.