DM-
SV01 Server ● BMC User Manual ● Rev. 2.1
86
Figure 84: Redfish - Current consumption
3.3.5.3.2 Power Consumption
Using a GET request, it is possible to retrieve the instantaneous total power being consumed by the
DM-SV01 server.
Function
System Total Power Consumption
Operation
GET
URI
https://<BMC_IP>/redfish/v1/Chassis/chassis/Sensors/total_power
Payload
none
Header
X-Auth-
Token: “<token>”
Expected
response
200 OK
Reply
Please, see the example below.
As an example, the excerpt below shows the data provided by the redfish when using the GET request
to retrieve the total power consumption of the system. The value of the power consumption is shown in
the “Reading” field. The measurement unit (Watts) is shown in the “ReadingUnits” field. Additionally,
the user can check the health status of the sensor and the respective warning and critical thresholds.