Code
Name
Severity
(Warning/
Error/Trip
lock)
Description LCP name
0x8694 Homing
error on
start homing
method
Warning
Could not
start homing
method (for
example
drive not in
standstill).
Homing
method fail
0x8695 Homing
error
distance
Warning
Homing
distance
reached.
Homing
distance
0xFF01 Mechanical
brake failure
Trip lock
No brake or
wire failure.
brake mech
fail
0xFF02 Short circuit
in
mechanical
brake
control
Trip lock
Short circuit
in brake
control.
brake mech
short
0xFF0A External
interface
power
failure
Error
External
interface
power
supply
failure.
ext IF pwr
fail
0xFF60 Timing
violation 1
Trip lock
Contact
Danfoss.
timing err 1
0xFF61 Timing
violation 2
Trip lock
Contact
Danfoss.
timing err 2
0xFF62 Timing
violation 3
Trip lock
Contact
Danfoss.
timing err 3
0xFF63 Timing
violation 4
Trip lock
Contact
Danfoss.
timing err 4
0xFF64 Timing
violation 5
Trip lock
Contact
Danfoss.
timing err 5
0xFF65 Timing
violation 6
Trip lock
Contact
Danfoss.
timing err 6
0xFF70 Firmware:
Package
description
mismatch
Trip lock
Firmware
found does
not match
the package
description.
FW pack err
0xFF71 Firmware:
Power cycle
needed
Warning,
error
Firmware
update
transfer is
completed
but a power
cycle is
required
before the
new
firmware is
active.
need
powercycle
Code
Name
Severity
(Warning/
Error/Trip
lock)
Description LCP name
0xFF72 Firmware:
Update
started
Warning,
error
Firmware
update in
progress.
The warning
becomes an
error when
an attempt
is made to
enable the
drive in this
state.
FW update
0xFF80 STO active
while drive
enabled
Error
STO
activated
while servo
drive was
enabled or
tried to
enable while
STO active.
STO active
0xFF81 STO
mismatch
Trip lock
Dual
diagnosis of
STO voltage
not
plausible.
STO
mismatch
0xFF85 P_STO error Trip lock
P_STO
voltage on
power card
not within
limits.
P_STO error
0xFF90 Guide value
reversed
Error
Position
guide value
went
backwards
while servo
drive in CAM
mode.
guide val rev
0xFF91 Guide value
implausible
Error
Increments
between
succeeding
values too
big.
guide val
impl
Table 9.2 Error Codes for Servo Drive
Diagnostics
VLT
®
Integrated Servo Drive ISD
®
510 System
76
Danfoss A/S © 12/2015 All rights reserved.
MG75K102