![Danfoss VLT Integrated Servo Drive ISD 510 System Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/danfoss/vlt-integrated-servo-drive-isd-510-system/vlt-integrated-servo-drive-isd-510-system_operating-instructions-manual_3555656026.webp)
130
BE693
.11
Auto
on
Reset
Hand
on
Off
Status
Quick
Menu
Main
Menu
Alarm
Log
Back
Can
cel
In
fo
OK
Status
11.5 A
2.1 kW
On
Alarm
Warn.
A
38 °C
24 V
B
C
D
565 V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Display
Description
1
U
AUX
line voltage
2
Temperature
3
Actual UDC (current)
4
ISD power consumption
5
Actual UDC (voltage)
Illustration 3.11 Display Area when Connected to the SAB
B. Display menu keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Key
Function
6
Status
Shows operational information.
7
Quick Menu
Allows access to parameters.
8
Main Menu
Allows access to parameters.
9
Alarm Log
Shows the last 10 alarms.
Table 3.18 Display Menu Keys
C. Navigation keys and indicator lights (LEDs)
Navigation keys are used for moving the display cursor
and provide operation control in local operation. There are
also 3 status LEDs in this area.
Key
Function
10 Back
Reverts to the previous step or list in the
menu structure.
11 Cancel
Cancels the last change or command as long
as the display mode is not changed.
12 Info
Press for a definition of the function being
shown.
13 Navigation
keys
Use the 4 navigation keys to move between
items in the menu.
14 OK
Use to access parameter groups or to enable
a selection.
Table 3.19 Navigation Keys
LED
Color
Function
15 On
Green
The
On
LED activates when the
ISD 510 servo drive or SAB it is
connected to receives power from
the mains or auxiliary supply, or a
DC bus terminal.
16 Warn
Yellow
When warning conditions are met,
the yellow
Warn
LED activates and
text appears in the display area
identifying the problem.
17 Alarm
Red
A fault condition causes the red
Alarm
LED to flash and an alarm
text is shown.
Table 3.20 Indicator Lights (LEDs)
System Description
VLT
®
Integrated Servo Drive ISD
®
510 System
24
Danfoss A/S © 12/2015 All rights reserved.
MG75K102
3
3
Содержание VLT Integrated Servo Drive ISD 510 System
Страница 2: ......
Страница 101: ...Index Operating Instructions MG75K102 Danfoss A S 12 2015 All rights reserved 99...