Code
Name
Severity
(Warning/
error/trip
lock)
Description
LCP name
0x3293
U
AUX
low voltage
Warning
U
AUX
below warning limit.
UAUX low volt
0x3294
U
AUX
undervoltage
Error
U
AUX
below undervoltage limit.
UAUX undervolt
0x3295
UDC high voltage
Warning
The DC-link voltage (DC) is higher than
the high-voltage warning limit.
UDC high volt
0x3296
UDC low voltage
Warning
The DC-link voltage (DC) is lower than
the low-voltage warning limit.
UDC low volt
0x4220
Too low temperature: Heat
sink
Warning
Heat sink temperature low. The SAB is
too cold to operate. This warning is
based on the temperature sensor in
the IGBT module. This warning only
occurs when DC-link voltage is >250 V.
low temp PM
0x4290
Overtemperature: Heat sink
Warning,
Error
The maximum temperature of the heat
sink has been exceeded. The
temperature fault does not reset until
the temperature drops below a defined
heat sink temperature (115
°
C).
overtemp PM
0x4291
Overtemperature: Control
card
Warning,
Error
Control card overtemperature.
The cutout temperature of the control
card is 80
°
C.
overtemp CC
0x4292
Overtemperature: SAB card
Warning,
Error
SAB card overtemperature.
The cutout temperature of the SAB
card is 80
°
C.
overtemp SC
0x4293
Inrush overtemperature: SAB
card
Error
Inrush fault. Too many transitions into
state
Normal operation
have occurred
within a short time period.
inrush SC
0x4294
Inrush overtemperature:
power module
Error
Inrush fault. Too many power-ups have
occurred within a short time period.
inrush PM
0x4410
Overtemperature: SAB
Error
Logic OR of control card temperature
(see 0x4291) and/or heat sink
temperature (see 0x4290) and/or SAB
card temperature (see 0x4292).
overtemp SAB
0x6320
Parameter error
Trip lock
A parameter has an invalid value.
param err
0x6380
Configuration error
(parameter missing)
Trip lock
A parameter is missing.
config err
0x6381
Reinitialization of parameters
from powercard
Trip lock
Configuration reinitialization.
Configuration parameter for power unit
has been reinitialized.
config reinit
0x7111
Brake chopper short circuit
Error
The brake chopper is monitored during
operation. This error appears if a short
circuit occurs.
brake ch short
0x7181
Brake resistor failure
Error
The brake resistor is monitored during
operation. This error appears if a short
circuit occurs.
brake r short