Illustration 6.13 TwinCAT
®
System Manager after Appending
the PLC Project and Adding an SAB and 2 Servo Drives
I/O configuration and I/O mapping
When connecting >1 servo drive, connect port C (X2) of
the previous drive to port A (X1) of the next servo drive.
The SAB port assignment must also be followed, see
. If the hardware set-up is already
present, the TwinCAT
®
System Manager
Scan devices
function can be used to automatically add the connected
devices to the configuration in the correct order.
The servo drive has to be configured so that the PDO
mapping matches the requirements of the library. This is
done inside the
TwinCAT
®
System Manager
.
1.
Click on the ISD servo drive entry.
2.
Select the
Slots
tab on the right side of the
window.
3.
Remove the current PDO configuration by
selecting the entry
Module 1 (CSV PDO)
in the
Slot
box.
4.
Click on
X
.
5.
Select Library PDO in the Module box.
6.
Click on
<
.
Illustration 6.14 ISD 510 Servo Drive with Correct I/O Configu-
ration
Attach the input and output variables of the PLC program
to the physical inputs and outputs of the device. This is
done inside the
TwinCAT
®
System Manager
so that the
library has access to all necessary objects.
1.
Select
Library TxPDO
via menu [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
®
)
→
Box 1
(VLT
®
Servo Access Box L1)
→
Drive 2 (VLT
®
ISD
510 Integrated Servo Drive)
→
Module 1 (Library
PDO)
→
Library TxPDO].
2.
Select all entries
Lib pdo tx1
to
Lib pdo tx9
on the
right side of the window (see
3.
Right-click and select
Change Multi Link…
.
4.
In the
Attach Variable 36.0 Byte(s) (Input)
window,
select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.TPDO].
Ensure that the
Matching Size
option is selected
in the
Attach Variable
window.
5.
Click
OK
.
6.
Click on Library
RxPDO
via menu [I/O-Configu-
ration
→
I/O Devices
→
Device1 (EtherCAT
®
)
→
Box1 (VLT
®
Servo Access Box L1)
→
Drive2 (VLT
®
ISD 510 Integrated Servo Drive)
→
Module1
(Library PDO)
→
Library RxPDO].
7.
Select all entries
Lib pdo rx1
to
Lib pdo rx9
on the
right side of the window.
Commissioning
VLT
®
Integrated Servo Drive ISD
®
510 System
52