![Danfoss VLT Integrated Servo Drive ISD 510 System Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/danfoss/vlt-integrated-servo-drive-isd-510-system/vlt-integrated-servo-drive-isd-510-system_operating-instructions-manual_3555656055.webp)
8.
Right-click and select
Change Multi Link…
.
9.
In the
Attach Variable 36.0 Byte(s) (Output)
window
select [PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.RPDO].
10.
Click on
OK
.
11.
Right-click on
WcState
via [I/O-Configuration
→
I/O Devices
→
Device1 (EtherCAT
®
)
→
Box1 (VLT
®
Servo Access Box L1)
→
Drive2 (VLT
®
ISD 510
Integrated Servo Drive)
→
WcState] and select
Change Link…
.
12.
In the
Attach Variable State (Input)
window select
[PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.WcState.
13.
Click on
OK
.
14.
Right-click on
State
via [I/O-Configuration
→
I/O
Devices
→
Device1 (EtherCAT
®
)
→
Box1 (VLT
®
Servo Access Box L1)
→
Drive2 (VLT
®
ISD 510
Integrated Servo Drive)
→
InfoData] and select
Change Link…
.
15.
In the
Attach Variable State (Input)
window select
[PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.State.
16.
Click on
OK
.
17.
Right-click on
netId
via [I/O-Configuration
→
I/O
Devices
→
Device1 (EtherCAT
®
)
→
Box1 (VLT
®
Servo Access Box L1)
→
Drive2 (VLT
®
ISD 510
Integrated Servo Drive)
→
InfoData
→
AdsAddr]
and select
Change Link…
.
18.
In the
Attach Variable netId (Input)
window select
[PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.AmsNetId.].
19.
Click on
OK
.
20.
Right-click on
port
via [I/O-Configuration
→
I/O
Devices
→
Device1 (EtherCAT
®
)
→
Box1 (VLT
®
Servo Access Box L1)
→
Drive2 (VLT
®
ISD 510
Integrated Servo Drive)
→
InfoData
→
AdsAddr]
and select
Change Link…
.
21.
In the
Attach Variable port (Input)
window select
[PLC-Configuration
→
MyFirstIsd510Project
→
Standard
→
.myAxis.NodeNumber.].
22.
Click on
OK
.
Illustration 6.15 Attaching Inputs and Outputs to the Physical
Data Points
NOTICE
Repeat the steps 2–22 for Box 1 (VLT
®
Servo Access Box
L1) and the instance mySAB.
To transfer the mappings back to the PLC program, select
Activate Configuration…
in menu item
Actions
.
After a rebuild in
TwinCAT
®
PLC Control
, the TwinCAT
®
configuration is according to
(here
myAxis
and
mySecondAxis
are instances of
AXIS_REF_ISD51x
and
mySAB
is an instance of
SAB_REF
). The concrete addresses
can be different.
Illustration 6.16 TwinCAT
®
Configuration: I/O Mapping of 2
Servo Drives and an SAB
Commissioning
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.
53
6