LED
Color
Flash status
Description
Aux 2 Green –
State of the auxiliary
voltage on line 2.
On
Statemachine is in
state
Standby
,
Power
up
, or
Operation
enabled
. Auxiliary
voltage is applied to
the output connectors
on line 2.
Off
Statemachine is in
state
U
AUX
disabled
or
Fault
. Auxiliary voltage
is not applied to line 2.
Safe 1 Green On
24 V for STO is present
on line 1.
Off
24 V for STO is not
present on line 1.
Safe 2 Green On
24 V for STO is present
on line 2.
Off
24 V for STO is not
present on line 2.
SAB
STAT
Green On
SAB is in state
Operation enabled
.
Flashing
Auxiliary voltage is
applied at the input.
Off
No auxiliary voltage is
applied at the input.
Red
On
The SAB is in state
Fault
.
Flashing
Mains is not applied at
the input.
NET
STAT
Green/
red
Fieldbus dependent.
Network status of the
device (see
corresponding fieldbus
standard).
Link/A
CT X1
Green –
Link/activity status of
In
.
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
Link/A
CT X2
Green –
Link/activity status of
Out
.
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
LED
Color
Flash status
Description
Link/A
CT X3
Green –
Link/activity status of
line 1.
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
Link/A
CT X4
Green –
Link/activity status of
line 2.
On
Ethernet link
established.
Flashing
Ethernet link
established and active.
Off
No link.
Table 7.4 Legend to
Operation
Operating Instructions
MG75K102
Danfoss A/S © 12/2015 All rights reserved.
65