9.3.2 Error Codes
Code
Name
Severity
(Warning/
error/trip
lock)
Description
LCP name
0x0000
No error
Error
No error.
–
0x1000
Generic application error
Error
Generic application error.
generic err
0x2120
Ground fault
Error
There is current from the output
phases to ground.
ground fault
0x2340
Short circuit
Error
There is a short circuit in UDC output
from SAB (DC Line1 and/or DC Line2).
Remove power to the SAB and repair
the short circuit.
short circuit
0x2391
AUX 1 overcurrent
Error
Current on AUX Line 1 reached
overcurrent limit.
AUX1 overcurr
0x2392
AUX 2 overcurrent
Error
Current on AUX Line 2 reached
overcurrent limit.
AUX2 overcurr
0x2393
AUX 1 user limit current
Warning,
error
Current on AUX Line 1 reached user-
defined limit.
AUX1 curr limit
0x2394
AUX 2 user limit current
Warning,
error
Current on AUX Line 2 reached user-
defined limit.
AUX2 curr limit
0x2395
AUX 1 fuse failure
Error
HW fuse failure.
Current or voltage above limit on AUX
Line 1.
AUX1 fuse fail
0x2396
AUX 2 fuse failure
Error
HW fuse failure.
Current or voltage above limit on AUX
Line 2.
AUX2 fuse fail
0x2397
DC 1 overcurrent
Error
Overcurrent on DC Line 1. The SAB
peak current limit (approximately 200%
of the rated current) is exceeded.
DC1 overcurr
0x2398
DC 2 overcurrent
Error
Overcurrent on DC Line 2. The SAB
peak current limit (approximately 200%
of the rated current) is exceeded.
DC2 overcurr
0x2399
DC overcurrent
Error
Overcurrent. The SAB has reached the
current limit and shuts down to
prevent any damage to the hardware.
DC overcurr
0x239B
Overload on output (I2T)
Warning,
error
The SAB is about to cut out due to an
overload (more than 100% for too
long). The counter for electronic,
thermal SAB protection triggers a
warning at 90% and trips with an error
at 100%.
overload
0x239D
DC overcurrent
Warning,
error
Overcurrent. The SAB has reached the
current limit and shuts down to
prevent any damage to the hardware.
DC overcurr
0x3130
Mains phase loss
Warning,
error
Mains phase loss detected. This occurs
when a phase on mains is missing, or
when the mains is imbalanced.
phase loss
0x3210
DC link overvoltage
Error
The DC-link voltage exceeds the limit
and the SAB trips.
UDC overvolt
0x3220
DC link undervoltage
Error
The DC-link voltage is below the limit
and the SAB trips.
UDC undervolt
0x3291
U
AUX
high voltage
Warning
U
AUX
above warning limit.
UAUX high volt
0x3292
U
AUX
overvoltage
Error
U
AUX
above overvoltage limit.
UAUX overvolt
Diagnostics
VLT
®
Integrated Servo Drive ISD
®
510 System
78
Danfoss A/S © 12/2015 All rights reserved.
MG75K102
9
9
Содержание VLT Integrated Servo Drive ISD 510 System
Страница 2: ......