Frequency converter
P22K
P30K
P37K
P45K
P55K
P75K
P90K
Typical shaft output [kW]
22.0
30.0
37.0
45.0
55.0
75.0
90.0
Typical shaft output [hp]
30.0
40.0
50.0
60.0
70.0
100.0
125.0
IP54 frame
I6
I6
I6
I7
I7
I8
I8
Max. cable size in terminals (mains, motor) [mm
2
/AWG]
35/2
35/2
35/2
50/1
50/1
95/(3/0)
120/(4/0)
Output current
40
°
C ambient temperature
Continuous (3x380-440 V) [A]
44.0
61.0
73.0
90.0
106.0
147.0
177.0
Intermittent (3x380-440 V) [A]
48.4
67.1
80.3
99.0
116.6
161.7
194.7
Continuous (3x440-480 V) [A]
40.0
52.0
65.0
80.0
105.0
130.0
160.0
Intermittent (3x440-480 V) [A]
44.0
57.2
71.5
88.0
115.5
143.0
176.0
Max. input current
Continuous (3x380-440 V )[A]
41.8
57.0
70.3
84.2
102.9
140.3
165.6
Intermittent (3x380-440 V) [A]
46.0
62.7
77.4
92.6
113.1
154.3
182.2
Continuous (3x440-480 V) [A]
36.0
49.2
60.6
72.5
88.6
120.9
142.7
Intermittent (3 x 440-480 V) [A]
39.6
54.1
66.7
79.8
97.5
132.9
157.0
Max. mains fuses
Estimated power loss [W], best case/typical
1)
496
734
995
840
1099
1520
1781
Weight enclosure IP54 [kg]
27
27
27
45
45
65
65
Efficiency [%], best case/Typical
1)
98.0
97.8
97.6
98.3
98.2
98.1
98.3
Output current - 50
°
C ambient temperature
Continuous (3x380-440 V) [A]
35.2
48.8
58.4
63.0
74.2
102.9
123.9
Intermittent (3x380-440 V) [A]
38.7
53.9
64.2
69.3
81.6
113.2
136.3
Continuous (3x440-480 V) [A]
32.0
41.6
52.0
56.0
73.5
91.0
112.0
Intermittent (3x440-480 V) [A]
35.2
45.8
57.2
61.6
80.9
100.1
123.2
Table 8.5 3x380-480 V AC, P11K-P90K, I6-I8
1) At rated load conditions
General Specifications and ...
VLT
®
HVAC Basic Drive FC 101 Design Guide
102
MG18C502 - Rev. 2013-09-06
8
8
Содержание VLT HVAC Basic Drive FC 101
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT HVAC Basic Drive FC 101 www danfoss com drives...
Страница 2: ......
Страница 123: ...Index VLT HVAC Basic Drive FC 101 Design Guide MG18C502 Rev 2013 09 06 121...
Страница 124: ...www danfoss com drives MG18C502 130R0222 MG18C502 Rev 2013 09 05...