Par. No. # Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
16-61
Terminal 53 Switch Setting
[0] Current
All set-ups
FALSE
-
Uint8
16-62
Analog Input 53
0 N/A
All set-ups
FALSE
-3
Int32
16-63
Terminal 54 Switch Setting
[0] Current
All set-ups
FALSE
-
Uint8
16-64
Analog Input 54
0 N/A
All set-ups
FALSE
-3
Int32
16-65
Analog Output 42 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-66
Digital Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-67
Pulse Input #29 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-68
Pulse Input #33 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-69
Pulse Output #27 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-70
Pulse Output #29 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-71
Relay Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-72
Counter A
0 N/A
All set-ups
TRUE
0
Int32
16-73
Counter B
0 N/A
All set-ups
TRUE
0
Int32
16-75
Analog In X30/11
0 N/A
All set-ups
FALSE
-3
Int32
16-76
Analog In X30/12
0 N/A
All set-ups
FALSE
-3
Int32
16-77
Analog Out X30/8 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-8* Fieldbus & FC Port
16-80
Fieldbus CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-82
Fieldbus REF 1
0 N/A
All set-ups
FALSE
0
N2
16-84
Comm. Option STW
0 N/A
All set-ups
FALSE
0
V2
16-85
FC Port CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-86
FC Port REF 1
0 N/A
All set-ups
FALSE
0
N2
16-9* Diagnosis Readouts
16-90
Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
16-91
Alarm Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-92
Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
16-93
Warning Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-94
Ext. Status Word
0 N/A
All set-ups
FALSE
0
Uint32
16-95
Ext. Status Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-96
Maintenance Word
0 N/A
All set-ups
FALSE
0
Uint32
Table 4.15
4.1.15 18-** Info & Readouts
Par. No. # Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
18-0* Maintenance Log
18-00
Maintenance Log: Item
0 N/A
All set-ups
FALSE
0
Uint8
18-01
Maintenance Log: Action
0 N/A
All set-ups
FALSE
0
Uint8
18-02
Maintenance Log: Time
0 s
All set-ups
FALSE
0
Uint32
18-03
Maintenance Log: Date and Time
ExpressionLimit
All set-ups
FALSE
0
TimeOfDay
18-1* Fire Mode Log
18-10
FireMode Log:Event
0 N/A
All set-ups
FALSE
0
Uint8
18-11
Fire Mode Log: Time
0 s
All set-ups
FALSE
0
Uint32
18-12
Fire Mode Log: Date and Time
ExpressionLimit
All set-ups
FALSE
0
TimeOfDay
18-3* Inputs & Outputs
18-30
Analog Input X42/1
0 N/A
All set-ups
FALSE
-3
Int32
18-31
Analog Input X42/3
0 N/A
All set-ups
FALSE
-3
Int32
18-32
Analog Input X42/5
0 N/A
All set-ups
FALSE
-3
Int32
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
180
MG16H102 - VLT
®
is a registered Danfoss trademark
4
4