![Danfoss MCA 194 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/danfoss/mca-194/mca-194_operating-instructions-manual_3500232043.webp)
5.10 VLT
®
5000 Parameter Group 9
VLT 5000 series
FC 302 series
Parameter
904 PPO type select for DP
Not converted
Table 5.274 Conversion of Parameter 904
VLT 5000 series
FC 302 series
Parameter 915 PCD config write
9-15 PCD Write Configu-
ration
Options
[0] None
[0] None
[204] Minimum Reference [302] Minimum Reference
[205] Maximum
Reference
[203] Maximum Reference
[219] Catch up/slow
Down Value
[312] Catch up/slow
Down Value
[207] Ramp 1 Ramp up
Time
[341] Ramp 1 Ramp up
Time
[208] Ramp 1 Ramp
Down Time
[342] Ramp 1 Ramp
Down Time
[209] Ramp 2 Ramp up
Time
[351] Ramp 2 Ramp up
Time
[210] Ramp 2 Ramp
down Time
[352] Ramp 2 Ramp
down Time
[211] Jog Ramp Time
[380] Jog Ramp Time
[212] Quick Stop Ramp
Time
[381] Quick Stop Ramp
Time
[201] Motor Low Limit
[Hz]
[412] Motor Speed Low
Limit [Hz]
[202] Motor High Limit
[Hz]
[414] Motor Speed High
Limit [Hz]
[221] Torque Limit Motor
Mode
[416] Torque Limit Motor
Mode
[222] Torque Limit
Generator Mode
[417] Torque Limit
Generator Mode
[509] Bus Jog 1 Speed
[890] Bus Jog 1 Speed
[510] Bus Jog 2 Speed
[891] Bus Jog 2 Speed
Comments VLT
®
5000 supports more write signals. If a not-
supported signal is written then the corresponding
signal is set to
[0] None.
Table 5.275 Conversion of Parameter 915
VLT 5000 series
FC 302 series
Parameter 916 PCD config read
9-16 PCD Read Configu-
ration
Options
[0] None
[0] None
[538] Alarm word
[1472] VLT Alarm Word
[540] Warning word
[1473] VLT Warning Word
[541] Ext. status word
[1474] VLT Ext. status
Word
[600] Operating hours
[1500] Operating hours
[601] Running hours
[1501] Running hours
[602] kWh Counter
[1502] kWh Counter
[539] Control word
[1600] Control word
[516] Reference [Unit]
[1601] Reference [Unit]
[515] Reference %
[1602] Reference %
[534] Status word
[1603] Status word
[522] Power [kW]
[1610] Power [kW]
[523] Power [HP]
[1611] Power [HP]
[524] Motor voltage
[1612] Motor voltage
[518] Motor frequency
[1613] Motor frequency
[520] Motor current
[1614] Motor current
[557] Motor RPM
[1617] Motor speed
[526] Motor thermal
[1618] Motor thermal
[521] Torque
[1622] Torque %
[525] DC link voltage
[1630] DC link voltage
[536] Brake energy/s
[1632] Brake energy/s
[535] Brake energy/2 min [1633] Brake energy/2 min
[537] Heat sink temp.
[1634] Heat sink temp.
[527] Inverter Thermal
[1635] Inverter Thermal
[533] External reference
[1650] External reference
[532] Pulse reference
[1651] Pulse reference
[517] Feedback [Unit]
[1652] Feedback [Unit]
[528] Digital input
[1660] Digital input
[529] Analog input 53
[1662] Analog input 53
[530] Analog input 54
[1664] Analog input 54
[531] Analog input 60
[1664] Analog input 54
Table 5.276 Conversion of Parameter 916
VLT 5000 series
FC 302 series
Parameter
918 Station address
10-02 MAC ID
Range
0 - 63
0 - 63
Table 5.277 Conversion of Parameter 918
VLT 5000 series
FC 302 series
Parameter
927 Parameter edit
9-27 Parameter Edit
Options
[0] Disable
[0] Disable
[1] Enable
[1] Enable
Table 5.278 Conversion of Parameter 927
Parameter Mapping Lists
Operating Instructions
MG37E102
Danfoss A/S © Rev. 2014-03-06 All rights reserved.
41