VLT 5000 series

FC 302 series

Parameter

611 Data log: Motor frequency

Not converted

Table 5.234 Conversion of Parameter 611

 

VLT 5000 series

FC 302 series

Parameter

612 Data log: Motor voltage

Not converted

Table 5.235 Conversion of Parameter 612

 

VLT 5000 series

FC 302 series

Parameter

613 Data log: Motor current

Not converted

Table 5.236 Conversion of Parameter 613

 

VLT 5000 series

FC 302 series

Parameter

614 Data log: DC link voltage

Not converted

Table 5.237 Conversion of Parameter 614

 

VLT 5000 series

FC 302 series

Parameter 615 Fault log: Error

code

15-30 Alarm Log: Error
Code

Table 5.238 Conversion of Parameter 615

 

VLT 5000 series

FC 302 series

Parameter

616 Fault log: Time

15-32 Alarm Log: Time

Table 5.239 Conversion of Parameter 616

 

VLT 5000 series

FC 302 series

Parameter

617 Fault log: Value

15-31 Alarm Log: Value

Table 5.240 Conversion of Parameter 617

 

VLT 5000 series

FC 302 series

Parameter 618 Reset of kWh counter 15-06 Reset kWh Counter
Options

[0] No reset

[0] Do not reset

[1] Reset

[1] Reset counter

Table 5.241 Conversion of Parameter 618

 

VLT 5000 series

FC 302 series

Parameter 619 Reset of Hours

run

15-07 Reset Running Hours
Counter

Options

[0] No reset

[0] Do not reset

[1] Reset

[1] Reset counter

Table 5.242 Conversion of Parameter 619

 

VLT 5000 series

FC 302 series

Parameter 620 Operation mode

14-22 Operation Mode

Options

[0] Normal operation

[0] Normal operation

[1] Function with deactivated
inverter

Not supported

[2] Control card test

[2] Control card test

[3] Initialisation

[3] Initialisation

Table 5.243 Conversion of Parameter 620

 

VLT 5000 series

FC 302 series

Parameter

621 Name plate: VLT

® 

type

Not converted

Table 5.244 Conversion of Parameter 621

 

VLT 5000 series

FC 302 series

Parameter 622 Name plate: Power section

Not converted

Table 5.245 Conversion of Parameter 622

 

VLT 5000 series

FC 302 series

Parameter 623 Name plate: VLT

®

 ordering no.

Not converted

Table 5.246 Conversion of Parameter 623

 

VLT 5000 series

FC 302 series

Parameter 624 Name plate: Software version no. Not converted

Table 5.247 Conversion of Parameter 624

 

VLT 5000 series

FC 302 series

Parameter

625 Name plate: LCP ID no.

Not converted

Table 5.248 Conversion of Parameter 625

 

VLT 5000 series

FC 302 series

Parameter

626 Name plate: Data base ID

Not converted

Table 5.249 Conversion of Parameter 626

 

VLT 5000 series

FC 302 series

Parameter

627 Name plate: Power ID no.

Not converted

Table 5.250 Conversion of Parameter 627

 

VLT 5000 series

FC 302 series

Parameter 628 Name plate: Application type

Not converted

Table 5.251 Conversion of Parameter 628

 

VLT 5000 series

FC 302 series

Parameter 629 Name plate: Application type no. Not converted

Table 5.252 Conversion of Parameter 629

Parameter Mapping Lists

Operating Instructions

38

Danfoss A/S © Rev. 2014-03-06 All rights reserved.

MG37E102

5

5

Содержание MCA 194

Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT DeviceNet Converter MCA 194 VLT AutomationDrive FC 302 VLT 5000 www danfoss com drives...

Страница 2: ......

Страница 3: ...etwork 11 4 1 1 Setting the DeviceNet Address using the Hardware Switches 11 4 1 2 Setting the DeviceNet Address via 10 02 MAC ID 11 4 1 3 Start up 12 4 2 LED Behaviour 12 4 3 Initialisation 13 5 Para...

Страница 4: ...6 Troubleshooting 43 6 1 Step by step Troubleshooting 43 Index 44 Contents Operating Instructions 2 Danfoss A S Rev 2014 03 06 All rights reserved MG37E102...

Страница 5: ...up time in VLT 5000 is automatically linked to the corresponding ramp up time parameter in VLT AutomationDrive FC 302 NOTICE Some parameters in the VLT 5000 are not supported in the FC 302 and some F...

Страница 6: ...g input voltage 53 Analog input voltage2 54 Analog input voltage X30 113 Analog input voltage 60 Analog input current 54 Analog input current3 55 GND analog digital input voltage 55 GND analog digital...

Страница 7: ...synchronise set up changes made with running motor ensure that FC 302 set ups are linked This is done in 0 12 This Set up Linked to 1 5 Abbreviations AOC Application Oriented Control CTW Control Word...

Страница 8: ...is thus not to be used as a safety switch 3 Establish correct protective earthing of the equipment protect the user against supply voltage and protect the motor against overload in accordance with ap...

Страница 9: ...75 7 5 kW 11 75 kW 525 690 11 75 kW High voltage may be present even when the warning LED indicator lights are off Table 2 1 Discharge Time Also make sure that other voltage inputs have been disconne...

Страница 10: ...r coded on the DeviceNet connector Unlike the VLT 5000 the FC 302 DeviceNet connectors are colour coded to avoid swapping the bus wires 130BD826 10 5 4 2 3 1 24V GND Drain CAN_L CAN_H Illustration 3 1...

Страница 11: ...The adapter plates have the same footprints as VLT 5000 and have threaded holes for VLT AutomationDrive The adapter plate prevents damage that can occur from drilling new threaded holes in the backboa...

Страница 12: ...m one cable to the other When crossing is unavoidable ensure that the DeviceNet cable crosses motor and brake resistor cables at an angle of 90 NOTICE Observe relevant national and local regulations f...

Страница 13: ...nge comes into effect at the next power up and can be read in 10 02 MAC ID Using the hardware switches select an address range from 0 to 63 factory setting 63 according to Illustration 4 1 ON 1 OFF 0...

Страница 14: ...Device operational Green The DeviceNet option is operating in normal condition Standby Green The DeviceNet option needs commis sioning due to configuration missing incomplete or incorrect Minor fault...

Страница 15: ...ck Low 4000000 4 57 Warning Feedback High 4000000 6 10 Terminal 53 Low Voltage 0 00 Volt 6 20 Terminal 54 Low Voltage 0 00 Volt 6 22 Terminal 54 Low Current 0 00 Volt 5 51 Term 29 High Frequency 5000...

Страница 16: ...3 4 Setup 4 4 Setup 4 5 Active Setup 9 Active Setup Table 5 5 Conversion of Parameter 005 VLT 5000 series FC 302 series Parameter 006 Setup Copy 0 51 Set up Copy Options 0 No Copy 0 No Copy 1 1 2 2 3...

Страница 17: ...o 012 VLT 5000 series FC 302 series Parameter 013 Local Ctrl config Not converted Table 5 11 Conversion of Parameter 013 VLT 5000 series FC 302 series Parameter 014 Local Stop key 0 41 Off Key on LCP...

Страница 18: ...19 Conversion of Parameter 100 VLT 5000 series FC 302 series Parameter 101 Torque charac teristic 1 03 Torque Characteristics 1 04 Overload Mode 14 40 VT Level Options 1 High constant torque Par 1 03...

Страница 19: ...e 200 600 Volt 50 1000 V Table 5 23 Conversion of Parameter 103 VLT 5000 series FC 302 series Parameter 104 Motor frequency 1 23 Motor Frequency Range 20 1000 Hz 20 1000 Hz Table 5 24 Conversion of Pa...

Страница 20: ...tions 0 DC hold in start delay time 0 DC hold delay time 1 DC brake in start delay time 1 DC Brake delay time 2 Coasting in start delay time 2 Coast delay time 3 Start frequency voltage clockwise 3 St...

Страница 21: ...time Not converted Table 5 51 Conversion of Parameter 132 5 3 VLT 5000 Parameter Group 2 VLT 5000 series FC 302 series Parameter 200 Output Frequency Range Direction 4 10 Motor Speed Direction Options...

Страница 22: ...mp Type Options 0 Linear 0 Linear Write to p 340 350 and 382 3 Sin3 Shape S3 Par 3 40 2 S ramp Const Time Par 3 45 50 Par 3 46 50 Par 3 47 50 Par 3 48 50 Par 3 50 2 S ramp Const Time Par 3 55 50 Par 3...

Страница 23: ...low Down Value Range 0 00 100 0 00 100 Table 5 72 Conversion of Parameter 219 VLT 5000 series FC 302 series Parameter 221 Torque limit for motor mode 4 16 Torque Limit Motor Mode Range 0 0 Max torque...

Страница 24: ...kwise on 12 Enable start forward 4 Jog 14 Jog 5 Preset reference on 15 Preset reference on 6 Preset reference lsb 16 Preset reference bit 0 7 Freeze reference 17 Freeze reference 8 Freeze output 20 Fr...

Страница 25: ...t reference on 15 Preset reference on 7 Preset reference lsb 16 Preset reference bit 0 8 Preset reference msb 17 Preset reference bit 1 9 Freeze reference 19 Freeze reference 10 Freeze output 20 Freez...

Страница 26: ...tage 3 15 Reference 1 Source 7 00 Speed PID Feedback Source 1 93 Thermistor Source 4 20 Torque Limit Factor Source Options 0 No Operation Par 3 15 Reference resource 1 set to 0 No function 1 Reference...

Страница 27: ...current 3 17 Reference 3 Source 7 00 Speed PID Feedback Source 1 93 Thermistor Source 4 20 Torque Limit Factor Source Options 0 No Operation Par 3 17 Reference resource 3 set to 0 No function 1 Refere...

Страница 28: ...rque limit 12 Out of current range Par 5 32 12 Out of current range 13 Above I low Par 5 32 13 Below current low 1 14 Under I high Par 5 32 14 Above current high 1 Table 5 106 Conversion of Parameters...

Страница 29: ...minal 45 Output Digital Par 5 33 DO X30 7 MCB 101 Analogue values Par 6 60 AO X30 8 Pulse Par 5 66 DO X30 6 Options 43 Ref min Ref max 4 20 mA Par 6 50 131 Reference 4 20 mA 44 Ref min Ref max 0 32000...

Страница 30: ...tion Relay Range 01 Relay 04 Relay Relay 1 Relay 2 0 No function Par 5 40 0 No operation 1 Control Ready Par 5 40 1 Control Ready 2 Ready signal Par 5 40 2 Drive ready 3 Ready Remote Control Par 5 40...

Страница 31: ...le 5 117 Conversion of Parameter 327 VLT 5000 series FC 302 series Parameter 328 Pulse feedback max freq 5 56 5 50 5 55 Range 100 65000 Hz 0 110000 Hz Table 5 118 Conversion of Parameter 328 VLT 5000...

Страница 32: ...stop Table 5 128 Conversion of Parameter 400 VLT 5000 series FC 302 series Parameter 401 Brake resistor 30 81 Brake Resistor ohm Options Power unit dependable Power unit dependable Table 5 129 Conver...

Страница 33: ...rted Table 5 136 Conversion of Parameter 408 VLT 5000 series FC 302 series Parameter 409 Trip delay torque 14 25 Trip Delay at Torque Limit Range 0 60 s 60 OFF 0 60 s 60 OFF Table 5 137 Conversion of...

Страница 34: ...b ft 39 ft s 140 ft s 40 ft min 141 ft min Table 5 145 Conversion of Parameter 416 Part 2 VLT 5000 series FC 302 series Parameter 417 Speed PID propor tional gain 7 02 Speed PID propor tional gain Dat...

Страница 35: ...frequency 1 56 F4 frequency Data range 0 0 par 104 0 0 1000 0 Hz Table 5 159 Conversion of Parameter 430 VLT 5000 series FC 302 series Parameter 431 U5 voltage 1 55 U5 voltage Data range 0 0 par 103 0...

Страница 36: ...ameter 446 VLT 5000 series FC 302 series Parameter 447 Torque compensation Not supported Table 5 174 Conversion of Parameter 447 VLT 5000 series FC 302 series Parameter 448 Gear ratio Not supported Ta...

Страница 37: ...0 Fieldbus profile 1 ProfiDrive profile 1 FC profile 0 FC profile Table 5 188 Conversion of Parameter 512 VLT 5000 series FC 302 series Parameter 513 Bus time interval Not Converted Table 5 189 Conver...

Страница 38: ...rameter 532 VLT 5000 series FC 302 series Parameter 533 External reference 16 50 External Reference Table 5 209 Conversion of Parameter 533 VLT 5000 series FC 302 series Parameter 534 Status word bina...

Страница 39: ...603 VLT 5000 series FC 302 series Parameter 604 Numbers of over temp 15 04 Over Temp s Table 5 227 Conversion of Parameter 604 VLT 5000 series FC 302 series Parameter 605 Numbers of over voltage 15 05...

Страница 40: ...meter 620 Operation mode 14 22 Operation Mode Options 0 Normal operation 0 Normal operation 1 Function with deactivated inverter Not supported 2 Control card test 2 Control card test 3 Initialisation...

Страница 41: ...6 Conversion of Parameter 701 VLT 5000 series FC 302 series Parameter 702 PID Proportional factor 32 60 Proportional factor Options 0 65000 0 100000 Table 5 257 Conversion of Parameter 702 VLT 5000 se...

Страница 42: ...on of Parameters 795 to 799 5 9 VLT 5000 Parameter Group 8 VLT 5000 series FC 302 series Parameter 801 Baud rate selection Not converted Table 5 269 Conversion of Parameter 801 VLT 5000 series FC 302...

Страница 43: ...Warning word 1473 VLT Warning Word 541 Ext status word 1474 VLT Ext status Word 600 Operating hours 1500 Operating hours 601 Running hours 1501 Running hours 602 kWh Counter 1502 kWh Counter 539 Contr...

Страница 44: ...up Options 0 Factory setting 0 Factory setting 1 Parameter setup 1 1 Parameter setup 1 2 Parameter setup 2 2 Parameter setup 2 3 Parameter setup 3 3 Parameter setup 3 4 Parameter setup 4 4 Parameter s...

Страница 45: ...erter has no connection to the master this parameter may be set to the wrong baudrate Check 10 13 Warning Parameter Bit Warn Word Hex Description 0 0001 Bus not active 1 0002 Explicit connection timeo...

Страница 46: ...High voltage 6 I Installation 8 L LED 12 Linked set up 5 Literature 3 M MCA 194 43 Mechanical installation 9 P Parameter mapping list 14 Performance 5 Power size 3 Product overview 3 Q Qualified perso...

Страница 47: ...Index Operating Instructions MG37E102 Danfoss A S Rev 2014 03 06 All rights reserved 45...

Страница 48: ...to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of...

Отзывы: