Camera Performance and Features
A previously saved user setting (User Set 1 to 16) or the factory settings can be restored using the
user set selector and user set load features.
Either the factory setting or one of the user settings can be configured as the default setting, by
selecting the set in the user set default selector. The set selected is the set that is loaded and
becomes active when the camera is reset or powered up.
The relationship between the settings is illustrated in Figure 22. Relationship between the Camera
Figure 22. Relationship between the Camera Settings
Active Settings for Current Operation
Active settings are those settings used while the camera is running and include all unsaved
changes made by GenICam input to the settings.
These active settings are stored in the camera’s volatile memory and will be lost and cannot be
restored if the camera resets, is powered down, or loses power during operation.
To save these settings so that they can be restored next time you power up the camera, or to
protect against losing them in the case of power loss, you must save the current settings using the
user set save parameter. Once saved, the current settings become the selected user set.
Facrory Setting
Active Setting
By GenIcam Command
1. Select a ‘User Set’
2. Initiate a ‘User Set Load’
User Setting
By GenIcam Command
1. Select a ‘User Set’
2. Initiate a ‘User Set Save’
By GenIcam Command
1. Select a ‘Factory Set’
2. Initiate a ‘User Set Load’
By GenIcam GenIcam Command
1. Select ‘Default Set’ as Factory
(Saves Automatically)
By GenIcam Command
1. Select ‘Default Set’ as Uset Set #
(Saves Automatically)
Power Up
Or Reset
Power Up
Or Reset
GenIcam Input