22
•
Linea ML Multiline Monochrome / HDR CMOS Cameras
Setting Up for Imaging
Figure 11. Camera I / O Connectors: 8K FM (left) & 16K HM (right)
Camera I / O Connectors
1) Factory use only.
2) Data and control connectors: LC or CX4 AOC.
3) LED status indicators.
4) Power and GPIO connectors: +12 V to +24 V DC, Hirose 12-pin circular.
Powering the Camera
WARNING: When setting up the camera’s power supply follow these guidelines:
•
Apply the appropriate voltages of b12 V to +24 V. Incorrect voltages may damage
the camera.
•
Before connecting power to the camera, test all power supplies.
•
Protect the camera with a 3 amp slow-blow fuse between the power supply and the camera.
•
Do not use the shield on a multi-conductor cable for ground.
•
Keep leads as short as possible in order to reduce voltage drop.
•
Use high quality supplies in order to minimize noise.