5-38
E S P R E SS O “Z E RO BA R I STA” CO F F E E M AC H I N E S - O P E R AT I N G I N ST R U CT I O N S
GENERAL
SAFET
Y
GENERAL
DESCRIP
TION
USE
MAINTENANCE
TRANSP
OR
T AND
INS
TALLA
TION
ALARM
CODE
CAUSE
SOLUTION
Maximum steam boiler
temperature, sensor
interrupted
AB2
Temperature detected is higher than or
equal to 128°C
Switch OFF the machine and switch it ON
again
Minimum level in steam boiler
AL2
Minimum level sensor is uncovered
Resets automatically when the status of
sensor covered is detected
Filling timeout
AL1
Maximum level not reached within the set
time. First filling timeout 8 secs, next fillings
according to the value set in the machine
Switch OFF the machine and switch it ON
again.
Filter regeneration alarm
AMAI8
Number of scheduled liters reached
Access the info for liter counter procedure
in order to reset the alarm
Maintenance alarm
AMAI2
Date for scheduled maintenance reached
Access the info for maintenance procedure
in order to reset the alarm
Clock alarm
A01
Clock reading error since data read not
correct
Resets automatically when first correct
reading is made
MCS timeout
AMCS1
Set temperature not reached within 60 secs Resets at next selection for steam wand
Содержание ZERO BARISTA
Страница 1: ...ESPRESSO COFFEE MACHINES ZERO BARISTA TRANSLATION OF ISTRUZIONI ORIGINALI eng OPERATING INSTRUCTIONS ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...1 1 CHAPTER 1 GENERAL GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 1 GENERAL ...
Страница 17: ...2 1 CHAPTER 2 SAFETY GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 2 SAFETY ...
Страница 37: ...5 1 CHAPTER 5 USE GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 5 USE ...
Страница 85: ......
Страница 86: ...Via ZAMBELETTI 10 20021 Baranzate MI Italy T 39 02 454 865 43 info dallacorte com www dallacorte com ...