5-36
E S P R E SS O “Z E RO BA R I STA” CO F F E E M AC H I N E S - O P E R AT I N G I N ST R U CT I O N S
GENERAL
SAFET
Y
GENERAL
DESCRIP
TION
USE
MAINTENANCE
TRANSP
OR
T AND
INS
TALLA
TION
ALARM
CODE
CAUSE
SOLUTION
Lever serial communication
ALx2
The lever card does not dialogue with the
display card for more than 5 secs.
It resets automatically by re-establishing
the connection with the display card
Motor point 0 recalibration
AMx3
Motor has not finished the last command
imparted; e:g because of power failure;
number of pulses out of expected range; last
command terminated because of timeout,
the barista model has been configured,
during the test procedure the motor has
been put in motion
Reset by calibrating the point 0. During
some phases, this is made automatically
Brewing process timeout
AIx
Pulses of CV not read since 120 secs
To next dose
Motor movement timeout
AMx4
Motor has not reached the position in the
expected time
Reset by calibrating the point 0.
Flow calibration error
AMx5
Position of motor encoder lower than 20
Reset by calibrating the flow
Boiler heating timeout
AGx1
Boiler has not reached 40°C within 5 minutes
from heating activation
Reset by putting the machine in stand-by
and switching it On.
Содержание ZERO BARISTA
Страница 1: ...ESPRESSO COFFEE MACHINES ZERO BARISTA TRANSLATION OF ISTRUZIONI ORIGINALI eng OPERATING INSTRUCTIONS ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...1 1 CHAPTER 1 GENERAL GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 1 GENERAL ...
Страница 17: ...2 1 CHAPTER 2 SAFETY GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 2 SAFETY ...
Страница 37: ...5 1 CHAPTER 5 USE GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 5 USE ...
Страница 85: ......
Страница 86: ...Via ZAMBELETTI 10 20021 Baranzate MI Italy T 39 02 454 865 43 info dallacorte com www dallacorte com ...