5.14.2 Machine alarms
The MCS alarms are reserved.
ALARM
CODE
CAUSE
SOLUTION
Corrupted data
A00
Settings read by the EEPROM are out of
given range, the wrong value is replaced by
the default one.
Switch OFF the machine and switch it ON
again
Boiler heating timeout
AB1
The boiler has not reached 40°C within 10
minutes from heating function activation
Reset by putting the machine in stand-by
mode and switching it ON
Minimum temperature of MCS
steam wand
AMCS3
Temperature detected is lower than 0°C
Reset by making the calibration. It resets
automatically by solving the problem
Maximum temperature of MCS
steam wand
AMCS2
Temperature detected is higher than 151°C
It resets automatically by solving the
problem
Minimum steam boiler
temperature, short-circuited
sensor
AB3
Temperature detected is lower than 0°C
Switch OFF the machine and switch it ON
again.
Содержание ZERO BARISTA
Страница 1: ...ESPRESSO COFFEE MACHINES ZERO BARISTA TRANSLATION OF ISTRUZIONI ORIGINALI eng OPERATING INSTRUCTIONS ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 13: ...1 1 CHAPTER 1 GENERAL GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 1 GENERAL ...
Страница 17: ...2 1 CHAPTER 2 SAFETY GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 2 SAFETY ...
Страница 37: ...5 1 CHAPTER 5 USE GENERAL SAFETY GENERAL DESCRIPTION USE MAINTENANCE TRANSPORT AND INSTALLATION 5 USE ...
Страница 85: ......
Страница 86: ...Via ZAMBELETTI 10 20021 Baranzate MI Italy T 39 02 454 865 43 info dallacorte com www dallacorte com ...