Troubleshooting
SiUS041829E
90
Part 6 Service Diagnosis
Reference
4.13 DC Fan Lock
Error Code
E7
Method of Error
Detection
An error is determined with the high-voltage fan motor rotation speed detected by the Hall IC.
Error Decision
Conditions
The fan does not start in 15 ~ 30 seconds even when the fan motor is running.
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 11 minutes without any other error
Supposed
Causes
Disconnection of the fan motor
Foreign matter stuck in the fan
Defective fan motor
Defective outdoor unit PCB
Troubleshooting
Check No.16
(R20416)
Caution
YES
YES
NO
YES
NO
NO
YES
NO
T
u
rn on the power.
Rotate the fan.
Check No. 16
Check the rotation p
u
lse inp
u
t on
the o
u
tdoor
u
nit PCB (main PCB).
T
u
rn off the power and
reconnect the connector.
Remove the foreign
matters.
Replace the o
u
tdoor fan
motor.
Replace the o
u
tdoor
u
nit
PCB (main PCB).
Fan motor
connector disconnected?
Foreign matters
in or aro
u
nd the fan?
Replace the o
u
tdoor fan
motor.
Fan rotates
smoothly?
P
u
lse signal
generated?
Be s
u
re to t
u
rn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Содержание FTXR-T Series
Страница 17: ...SiUS041829E Part 2 Specifications 13 1 Specifications 14 Part 2 Specifications...
Страница 125: ...SiUS041829E Check Part 6 Service Diagnosis 121 18 class R25105 1 2 3 4 Multimeter...
Страница 127: ...SiUS041829E Check Part 6 Service Diagnosis 123 18 class R20704 W V U DC_P1 DC_N1...
Страница 139: ...SiUS041829E Piping Diagrams Part 8 Appendix 135 1 2 Outdoor Unit RX09 12RMVJU9 RX18RMVJU9 3D092207C 3D092220C...
Страница 143: ...SiUS041829E Operation Limit Part 8 Appendix 139 4 Operation Limit RX09 12 18RMVJU9 3D092209E...