SiUS041829E
Service Diagnosis
Part 6 Service Diagnosis
67
Notes
3. Service Diagnosis
3.1 Method 1
1. When
Timer Cancel
button is held down for 5 seconds,
00
is displayed on the temperature
display screen.
2. Press
Timer Cancel
button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
ARC466A36
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold
Timer Cancel
button down for 5 seconds. When the remote
controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
Refer to page 68.
No.
Code
No.
Code
No.
Code
No.
Code
1
00
11
H6
21
C5
31
U2
2
A5
12
H0
22
J3
32
EA
3
E7
13
A6
23
J6
33
AH
4
F3
14
U0
24
E5
34
FA
5
F6
15
C7
25
A1
35
H1
6
L3
16
A3
26
E1
36
P9
7
L4
17
H8
27
UA
37
E3
8
L5
18
H9
28
UH
38
H3
9
U4
19
C9
29
P4
10
E6
20
C4
30
H7
(R24045)
< ARC466 Series >
Timer Cancel
b
u
tton
Содержание FTXR-T Series
Страница 17: ...SiUS041829E Part 2 Specifications 13 1 Specifications 14 Part 2 Specifications...
Страница 125: ...SiUS041829E Check Part 6 Service Diagnosis 121 18 class R25105 1 2 3 4 Multimeter...
Страница 127: ...SiUS041829E Check Part 6 Service Diagnosis 123 18 class R20704 W V U DC_P1 DC_N1...
Страница 139: ...SiUS041829E Piping Diagrams Part 8 Appendix 135 1 2 Outdoor Unit RX09 12RMVJU9 RX18RMVJU9 3D092207C 3D092220C...
Страница 143: ...SiUS041829E Operation Limit Part 8 Appendix 139 4 Operation Limit RX09 12 18RMVJU9 3D092209E...