SiUS041829E
Troubleshooting
Part 6 Service Diagnosis
105
Notes
Reference
Troubleshooting
In case of
H9
,
J3
,
J6
H9
: Outdoor temperature thermistor
J3
: Discharge pipe thermistor
J6
: Outdoor heat exchanger thermistor
When replacing the defective thermistor(s), replace the thermistors as ASSY.
Check No.01
(R20406)
Caution
NO
YES
YES
NO
NO
YES
T
u
rn on the power again.
Normal?
Reconnect the connectors
or thermistors.
J3
error: the discharge
pipe temperat
u
re is
lower than the heat
exchanger temperat
u
re.
Replace the defective
thermistor(s) of the following
thermistors.
O
u
tdoor temperat
u
re
thermistor
Discharge pipe thermistor
O
u
tdoor heat exchanger
thermistor
Cooling: O
u
tdoor heat
exchanger
temperat
u
re
Heating: Indoor heat
exchanger
temperat
u
re
Replace the indoor heat
exchanger thermistor.
Replace the o
u
tdoor
u
nit
PCB (main PCB).
Error displayed
again on remote
controller?
Indoor heat
exchanger thermistor
f
u
nctioning?
Check No. 01
Check the thermistor resistance
val
u
e.
Check No. 01
Check the indoor heat exchanger
thermistor resistance val
u
e in the
heating operation.
Be s
u
re to t
u
rn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Содержание FTXR-T Series
Страница 17: ...SiUS041829E Part 2 Specifications 13 1 Specifications 14 Part 2 Specifications...
Страница 125: ...SiUS041829E Check Part 6 Service Diagnosis 121 18 class R25105 1 2 3 4 Multimeter...
Страница 127: ...SiUS041829E Check Part 6 Service Diagnosis 123 18 class R20704 W V U DC_P1 DC_N1...
Страница 139: ...SiUS041829E Piping Diagrams Part 8 Appendix 135 1 2 Outdoor Unit RX09 12RMVJU9 RX18RMVJU9 3D092207C 3D092220C...
Страница 143: ...SiUS041829E Operation Limit Part 8 Appendix 139 4 Operation Limit RX09 12 18RMVJU9 3D092209E...