Instruction
SiENBE04-507A
88
System Configuration
To change the air flow rate setting
5. Press “FAN setting button”.
•
Indoor unit quiet operation
When the air flow is set to “
”, the noise from the indoor unit will become quieter.
Use this when making the noise quieter.
The unit might lose capacity when the air flow rate is set to a weak level.
NOTE
DRY mode
AUTO or COOL or HEAT or FAN mode
The air flow rate setting is not variable.
Five levels of air flow rate setting from “
” to “
”
plus “
” “
” are available.
Note on HEAT operation
•
Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating
capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it
is recommended to use another heating appliance in combination with the air conditioner.
•
The heat pump system heats the room by circulating hot air around all parts of the room. After
the start of heating operation, it takes some time before the room gets warmer.
•
In heating operation, frost may occur on the outdoor unit and lower the heating capacity. In
that case, the system switches into defrosting operation to take away the frost.
•
During defrosting operation, hot air does not flow out of indoor unit.
Note on DRY operation
•
The computer chip works to rid the room of humidity while maintaining the temperature as
much as possible. It automatically controls temperature and fan strength, so manual
adjustment of these functions is unavailable.
Note on AUTO operation
•
In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT)
based on the room temperature at the start of the operation.
•
The system automatically reselects setting at a regular interval to bring the room temperature
to usersetting level.
•
If you do not like AUTO operation, you can manually select the operation mode and setting
you like.
Note on air flow rate setting
•
At smaller air flow rates, the cooling (heating) effect is also smaller.
Содержание FTKS20DVMW(L)
Страница 10: ...SiENBE04 507A List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 16: ...SiENBE04 507A Specifications 7 Part 2 Specifications 1 Specifications 8 1 1 Cooling Only 8 1 2 Heat Pump 21...
Страница 53: ...Printed Circuit Board Connector Wiring Diagram SiENBE04 507A 44 Printed Circuit Board Connector Wiring Diagram...
Страница 85: ...Control Specification SiENBE04 507A 76 Function and Control...
Страница 159: ...Check SiENBE04 507A 150 Service Diagnosis...
Страница 198: ...SiENBE04 507A Outdoor Unit Removal Procedure 189 When reassembling make sure to fit the hook Step Procedure Points Hook...
Страница 212: ...SiENBE04 507A Others 203 Part 8 Others 1 Others 204 1 1 Test Run from the Remote Controller 204 1 2 Jumper Settings 205...
Страница 215: ...Others SiENBE04 507A 206 Others...
Страница 221: ...Wiring Diagrams SiENBE04 507A 212 Appendix...
Страница 225: ...SiENBE04 507A iv Index...