Main Functions
Function and Control
55
1.9
INTELLIGENT EYE
This is the function that detects existence of humans in the room by a human motion sensor
(INTELLIGENT EYE) and reduces the capacity when there is no human in the room in order to
save electricity.
Processing
1. Detection method by INTELLIGENT EYE
This sensor detects human motion by receiving infrared rays and displays the pulse wave
output.
A microcomputer in an indoor unit carries out a sampling every 20 msec. and if it detects 10
cycles of the wave in one second in total (corresponding to 20msec.× 10 = 100msec.), it
judges human is in the room as the motion signal is ON.
2. The motions (for example: in cooling)
When a microcomputer doesn’t have a signal from the sensor in 20 minutes, it judges that
nobody is in the room and operates the unit in temperature sifted 2°C from the set
temperature. (COOL : 2°C higher, DRY: 1°C higher, AUTO : according to the operation mode
at that time.)
H
1 In case of FAN mode, the fan speed reduces by 50 rpm.
If the sensor detects the outputs 10 times/sec.
or more, it judges humans exist.
1sec
sampling (20msec)
High
Low
ON
OFF
Sensor output
(Human motion)
Human detection
signal
(R2821)
Cooling : Set temp. + 2°C
Heating : Set temp. - 2°C
Human detection
signal
Compressor
speed
Remote control
Intelligent Eye
button
Operation
Fan speed (
H
1)
ON
OFF
ON
OFF
ON
OFF
OFF
MinHz
0Hz
MaxHz
Set temp.
RESET.
The lower limit by detecting
human.
(Prohibition of thermostat-off)
in case of
thermostat-off
Set speed - 50 rpm
Set speed
Set speed
Frequency at set temp. + 2°C
40 min.
20 min.
within 20
minutes. 20
min.
(R2822)
Содержание FTKS20DVMW(L)
Страница 10: ...SiENBE04 507A List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Страница 16: ...SiENBE04 507A Specifications 7 Part 2 Specifications 1 Specifications 8 1 1 Cooling Only 8 1 2 Heat Pump 21...
Страница 53: ...Printed Circuit Board Connector Wiring Diagram SiENBE04 507A 44 Printed Circuit Board Connector Wiring Diagram...
Страница 85: ...Control Specification SiENBE04 507A 76 Function and Control...
Страница 159: ...Check SiENBE04 507A 150 Service Diagnosis...
Страница 198: ...SiENBE04 507A Outdoor Unit Removal Procedure 189 When reassembling make sure to fit the hook Step Procedure Points Hook...
Страница 212: ...SiENBE04 507A Others 203 Part 8 Others 1 Others 204 1 1 Test Run from the Remote Controller 204 1 2 Jumper Settings 205...
Страница 215: ...Others SiENBE04 507A 206 Others...
Страница 221: ...Wiring Diagrams SiENBE04 507A 212 Appendix...
Страница 225: ...SiENBE04 507A iv Index...