PCB2 - Control PCB
The illustration below shows the PCB2 connectors.
Connectors
The table below describes the PCB connectors.
X40A
X18A
X57A
X16A
X36A
X30A
X24A
X15A
X33A
X6A
X35A
X58A
Connector
Connected to
Description
X6A
_
Not used
X15A
S1L
Float switch
X16A
A3P
Humidity sensor
X18A
R2T
Coil thermistor
X24A
X2A on A4P
X24A is connected when the wireless remote control used
X30A
X1M
Terminal strip for P1/P2 and F1/F2
X33A
X1A on KRP1B
Connector for wiring adaptor KRP1B
X35A
X1A on KRP4
Connector to group control adaptor power supply (16VDC)
for optional PCB KRP4
X36A
M1S
Swing flap motor
X40A
_
Not used
X57A
X54A/X55A (on A1P)
PCB interconnection wiring
X58A
X56A (on A1P)
PCB interconnection wiring
Содержание FHQ100BUV3B
Страница 1: ...Service Manual ESIE05 04 R 410A Sky Air Indoor...
Страница 2: ......
Страница 20: ...ESIE05 04 1 2 Part 1 System Outline 3 1 1 5...
Страница 62: ...General Outline ESIE05 04 1 44 Part 1 System Outline 3 1 1 4 5...
Страница 78: ...ESIE05 04 1 60 Part 1 System Outline...
Страница 112: ...Wiring Diagrams ESIE05 04 1 94 Part 1 System Outline 3 1 1 4 5...
Страница 140: ...ESIE05 04 2 2 Part 2 Functional Description 3 1 2 5...
Страница 164: ...ESIE05 04 3 2 Part 3 Troubleshooting 3 1 3 5...
Страница 206: ...Error Codes ESIE05 04 3 44 Part 3 Troubleshooting 3 1 3 4 5...
Страница 224: ...Additional Checks for Troubleshooting ESIE05 04 3 62 Part 3 Troubleshooting 3 1 3 4 5...
Страница 226: ...ESIE05 04 4 2 Part 4 Commissioning and Test Run 3 1 4 5...
Страница 252: ...ESIE05 04 5 2 Part 5 Disassembly and Maintenance 3 1 5...
Страница 384: ...Disassembly and Maintenance ESIE05 04 5 134 Part 5 Disassembly and Maintenance 3 1 5 5...
Страница 390: ...ESIE05 04 vi Index 3 1 4 5 W Wiring diagrams Indoor units k 1 61...