General Outline
ESIE05-04
1–6
Part 1 – System Outline
3
1
1
4
5
1.3
FCQ100, 125B
Outlook and
dimensions
The illustration below shows the outlook and the dimensions of the unit (mm).
P
rep
ared
hol
e
B
ranch d
u
ct
connect
io
n
or mo
re
Installa
tion space
REQUIRED I
N
S
T
AL
L
A
T
ION
S
P
ACE
WHEN T
H
E
DI
SCHARG
E G
R
IL
L
I
S
CL
O
SED,
T
H
E REQ
UI
RED SPACE
I
S
2
0
0
m
m
O
R
M
O
RE.
o
r
m
o
re
o
r
m
o
re
o
r
m
o
re
VIEW
D
P
repar
ed h
o
le
B
ra
n
ch duct
con
nection
P
repa
red h
o
le
VIEW B
(Suspen
sio
n posi
tio
n)
(Cei
ling openi
ng)
B
ranch d
u
ct
connect
ion
or
less
(C
e
ili
n
g
ope
ni
ng)
(S
usp
ensi
on posi
ti
on)
F
o
r fr
esh air
intake
ki
t
conn
ection (
d
ire
c
t
installa
tion type
)
VIEW
C
P
repar
ed ho
le
H
ang
in
g bol
t
Adju
sta
ble
NO
TES:
1.
Lo
cati
o
n
o
f the
na
me
pl
at
es:
- Un
it b
ody:
on
the
be
ll m
o
uth
at
the
inside
of
the
suct
ion
gr
ill.
- De
cor
a
tio
n p
ane
l: on
th
e p
ane
l fr
a
m
e
at
the
inside
of
the
suc
tion
gr
ill.
2.
Whe
n
ins
talling
an
op
tiona
l acc
e
sso
ry
, r
e
fe
r t
o
th
e in
stalla
tion
dr
a
wing
s
.
- F
o
r th
e fr
esh
air
inta
ke kit
.....
an
insp
ectio
n p
o
rt
is ne
cessa
ry
- F
o
r th
e hig
h e
fficien
cy filt
er
.....
an
inspe
ction
po
rt
is
ne
cessa
ry
- F
o
r th
e br
an
ch d
u
ct
cham
be
r .
... a
n
in
spec
tion
por
t is n
e
ce
ssar
y
VIEW A
P
repar
ed h
o
le
B
ranch
duct
conn
ection
o
r
m
o
re
see n
o
te 3
o
r
m
o
re
3
.
In
cas
e
of
usin
g a
wir
e
le
ss r
e
m
o
te
con
tr
o
lle
r,
this p
o
sitio
n will b
e
a
sign
a
l
re
cei
ve
r. R
e
fer to
t
he dr
aw
in
g of the
w
ir
e
le
ss
re
m
o
te
co
ntr
ol
le
r for m
o
re
deta
ils
.
4
.
Whe
n
t
he
cond
ition
s
exc
eed
30
°C a
nd
RH 80
%
in th
e ce
iling o
r f
res
h air
is
ind
u
ct
ed
into
th
e c
e
iling
, a
n
a
d
d
it
iona
l ins
u
latio
n
is
r
e
qu
ir
ed
(
p
olye
thyle
ne
foa
m
,
th
ickne
ss 10
mm
or
m
o
re
).
Содержание FHQ100BUV3B
Страница 1: ...Service Manual ESIE05 04 R 410A Sky Air Indoor...
Страница 2: ......
Страница 20: ...ESIE05 04 1 2 Part 1 System Outline 3 1 1 5...
Страница 62: ...General Outline ESIE05 04 1 44 Part 1 System Outline 3 1 1 4 5...
Страница 78: ...ESIE05 04 1 60 Part 1 System Outline...
Страница 112: ...Wiring Diagrams ESIE05 04 1 94 Part 1 System Outline 3 1 1 4 5...
Страница 140: ...ESIE05 04 2 2 Part 2 Functional Description 3 1 2 5...
Страница 164: ...ESIE05 04 3 2 Part 3 Troubleshooting 3 1 3 5...
Страница 206: ...Error Codes ESIE05 04 3 44 Part 3 Troubleshooting 3 1 3 4 5...
Страница 224: ...Additional Checks for Troubleshooting ESIE05 04 3 62 Part 3 Troubleshooting 3 1 3 4 5...
Страница 226: ...ESIE05 04 4 2 Part 4 Commissioning and Test Run 3 1 4 5...
Страница 252: ...ESIE05 04 5 2 Part 5 Disassembly and Maintenance 3 1 5...
Страница 384: ...Disassembly and Maintenance ESIE05 04 5 134 Part 5 Disassembly and Maintenance 3 1 5 5...
Страница 390: ...ESIE05 04 vi Index 3 1 4 5 W Wiring diagrams Indoor units k 1 61...