Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.6.4
[8-02]
R/W
0~10 hour, step: 0,5 hour
[E-07]=1:
0,5 hour
[E-07]
≠
1:
3 hour
9.6.5
[8-00]
R/W
0~20 min, step: 1 min
1 min
9.6.6
[8-01]
R/W
5~95 min, step: 5 min
30 min
9.6.7
[8-04]
R/W
0~95 min, step: 5 min
95 min
Installer settings
9.7
[4-04]
R/W
0: Continuous pump operation
1: Non continuous pump operation
2: OFF
└─
Benefit kWh power supply
9.8.2
[D-00]
R/W
0: No
1: Only BSH
2: Only BUH
3: All
9.8.3
[D-05]
R/W
0: No
1: Yes
9.8.4
[D-01]
R/W
0: No
1: Open
2: Closed
3: Smart Grid
9.8.6
R/W
0: No
1: Yes
9.8.7
Enable Room buffering
R/W
0: No
1: Yes
9.8.8
R/W
0~20 kW, step: 0,5 kW
2 kW
└─
Power consumption control
9.9.1
[4-08]
R/W
0: No
1: Continuous
2: Inputs
3: Current Sensor
9.9.2
[4-09]
R/W
0: Amp
1: kW
9.9.3
[5-05]
R/W
0~50 A, step: 1 A
50 A
9.9.4
[5-05]
R/W
0~50 A, step: 1 A
50 A
9.9.5
[5-06]
R/W
0~50 A, step: 1 A
50 A
9.9.6
[5-07]
R/W
0~50 A, step: 1 A
50 A
9.9.7
[5-08]
R/W
0~50 A, step: 1 A
50 A
9.9.8
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.9
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.A
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.B
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.C
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
9.9.D
[4-01]
R/W
0: None
1: Booster Heater
2: Backup Heater
9.9.F
[7-07]
R/W
0: No
1: Yes
└─
Energy metering
9.A.1
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.A.2
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
└─
Sensors
9.B.1
[C-08]
R/W
0: No
1: Outdoor
2: Room
9.B.2
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
9.B.3
[1-0A]
R/W
0: No
1: 12 h
2: 24 h
3: 48 h
4: 72 h
└─
Bivalent
9.C.1
[C-02]
R/W
0: No
1: Yes
Limit 2
Allow heater
Allow pump
Power consumption control
Type
Limit
Limit 1
Benefit kWh power supply
Allow electric heaters
Limit setting kW
Limit 4
Limit
Limit 1
Anti-recycle timer
Minimum running timer
Maximum running timer
Additional timer
Water pipe freeze prevention
Limit 2
Limit 3
Limit 3
Limit 4
Priority heater
BBR16 activation*
*BBR16 settings are only visible when the language of the user interface is set to
Swedish
Electricity meter 1
Electricity meter 2
External sensor
Ext. amb. sensor offset
Averaging time
Bivalent
(*1)
*6V*_(*2)
*9W*_
(*3)
ELB*_(*4)
ELV*_
(*5)
*X*_(*6)
*H*