13/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
3
9.I
[F-03]
5
9.I
[F-04]
0
9.I
[F-05]
0
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
R/W
0: No
1: Yes
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
Bizone kit settings
9.P.1
[E-0B]
R/W
0: Not installed
1: -
2: Bizone kit installed
9.P.2
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.P.3
[7-0A]
R/W
20~95%, step: 5%
95%
9.P.4
[7-0B]
R/W
20~95%, step: 5%
95%
9.P.5
[7-0C]
R/W
20~300 sec, step: 5 sec
125 sec
Main zone pump fixed PWM
--
--
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Close shut-off valve during cooling?
Bi-zone kit installed
Bi-zone system type
Add zone pump fixed PWM
Mixing valve turning time
What is the pump operation mode?
Above which outdoor temperature is cooling allowed?
--
--
(*1)
*6V*_(*2)
*9W*_
(*3)
ELB*_(*4)
ELV*_
(*5)
*X*_(*6)
*H*
4P717809
‐
1
–
2022.11