3
|
Specific installer safety instructions
Installer reference guide
19
ERRA08~12E + ELVH/23E
Daikin Altherma 3 R MT F
4P708474-1 – 2023.05
WARNING
▪
Only use R32 as refrigerant. Other substances may cause explosions and
accidents.
▪
R32 contains fluorinated greenhouse gases. Its global warming potential (GWP)
value is 675. Do NOT vent these gases into the atmosphere.
▪
When charging refrigerant, ALWAYS use protective gloves and safety glasses.
Electrical installation (see
WARNING
Make sure that the electrical wiring does NOT touch the refrigerant gas pipe, which
can be very hot.
a
a
Refrigerant gas pipe
DANGER: RISK OF ELECTROCUTION
WARNING
Electrical wiring connection method MUST be in accordance with the instructions
from:
▪
▪
The wiring diagram of the outdoor unit, which is delivered with the unit, located
at the inside of the service cover. For a translation of its legend, see
298].
▪
The wiring diagram of the indoor unit, which is delivered with the unit, located on
the inside of the indoor unit switch box cover. For a translation of its legend, see
"17.5 Wiring diagram: Indoor unit"
303].
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
▪
All wiring MUST be performed by an authorised electrician and MUST comply
with the applicable national wiring regulation.
▪
Make electrical connections to the fixed wiring.
▪
All components procured on-site and all electrical construction MUST comply
with the applicable legislation.