9
|
Electrical installation
Installer reference guide
152
ERRA08~12E + ELVH/23E
Daikin Altherma 3 R MT F
4P708474-1 – 2023.05
L
N
L
N
2
1
A
X10M.1
X10M.2
X10M.3
X10M.4
1
High voltage Smart Grid contact 1
2
High voltage Smart Grid contact 2
B
A
B
X5M
1 2 3 4
X10M
4
Fix the cables with cable ties to the cable tie mountings. If necessary, bundle
excessive cable length with a cable tie.
9.3.12 To connect the WLAN cartridge (delivered as accessory)
[D]
Wireless gateway
1
Insert the WLAN cartridge into the cartridge slot on the user interface of the
indoor unit.
1
2
9.4 After connecting the electrical wiring to the indoor unit
To prevent water ingress to the switch box, seal the low voltage wiring intake using
the sealing tape (delivered as accessory).